Pistola Pulverizadora HVLP Alimentada por Gravedad
Puede escribirnos a:
Campbell Hausfeld
Attn: Parts Department
100 Production Drive
Harrison, OH 45030 U.S.A.
12
10
13
15
14
16
11
17
14
18
19
20
21
29
28
33
HVLP Test Cap Kit
Kit de test de
capuchon HVLP
Juego de tapa de
prueba HVLP
24 Sp
Operating Instructions and Parts Manual
Maintenance
(Continued)
3. Remove and check the fluid needle
for excessive wear at the tip and
straightness.
IMPORTANT: If the needle tip is worn
more on one side than the other,
either the needle is bent or the gun
body has been dropped or knocked
out-of-line. There are no adjustments
that can be made to a bent gun body.
Test the needle by rolling on a flat
surface. Replace if necessary.
4. Check and replace any damaged o-
rings and seals. O-rings and seals
can be wiped clean but not soaked
in solvent.

Troubleshooting Chart

32
Symptom
Right or left
heavy spray
pattern
Top or bot-
31
tom heavy
spray pat-
tern
30
Split spray
pattern
Center
heavy spray
pattern
Sputtering
spray
Fluid leaking from packing
nut
Air leaking from air cap
without pulling trigger
5. Unscrew packing nuts and replace
the packing ONLY if a leak will not
stop when the nut is tightened (See
Figure 5). Do not over-tighten a
packing nut because this will
restrict movement of the needle.
6. Re-assemble in reverse order of
above and use a non-silicone oil on
moving parts. Apply Vaseline
®
or
light grease on threaded joints and
hose connections.
STORING
1. When not using spray gun, turn the
fluid adjustment knob counter-
clockwise to open which will reduce
spring tension on needle fluid tip.
2. Spray gun MUST BE well cleaned
and lightly lubricated.
Possible Cause(s)
Corrective Action
1.
Clean. Use only non-metallic point
1.
Holes in left or right side of the air
cap are plugged
2.
Clean
2.
Dirt on left or right side of fluid tip
1.
Clean
1.
Dried material at top or bottom of
fluid tip
2.
Loose air cap or dirty seat
2.
Clean and tighten
3.
Air cap plugged
3.
Clean. Use only non-metallic point
1.
Partially close the pattern adjustment
1.
Fan pattern open too far
2.
Fluid turned in too far
2.
Increase fluid
3.
Reduce atomization air pressure
3.
Atomization air too high
1.
Open fan pattern adjustment
1.
Fan adjustment partially closed
2.
Thin to proper viscosity
2.
Material too thick
3.
Increase atomization pressure
3.
Atomization pressure too low
1.
Material level too low
1.
Refill
2.
Container tipped too far
2.
Hold more upright
3.
Loose fluid inlet connection
3.
Tighten
4.
Loose or damaged fluid tip/seat
4.
Adjust or replace
5.
Dry or loose fluid needle packing nut
5.
Lubricate and or tighten
6.
Air vent clogged
6.
Clear vent hole
1.
Packing nut loose
1.
Tighten, but do not restrict needle
2.
Packing worn or dry
2.
Replace or lubricate (non-silicone oil)
1.
Sticking air valve stem
1.
Lubricate
2.
Contaminate on air valve or seat
2.
Clean
3.
Worn or damaged air valve or seat
3.
Replace
4.
Broken air valve spring
4.
Replace
5.
Bent valve stem
5.
Replace
5
HVLP Gravity Feed Spray Gun