Empty enclosures characteristics
Material:
Temperature:
IP-Rating:
WARNING
ATEX or IECEx use:
The complete assembled enclosure must be certified by a
recognised, notified body and in line with the ATEX directives or
IECEx scheme!
Marking:
Directive (RL) 94/9
II 2G Ex e IIC Gb
II 2(1)G Ex e ia IIC Gb
II 1G Ex ia IIC Ga
II2D Ex tb IIIC Db IP6X
IECEx
Ex e IIC Gb
Ex ia IIC Ga
Ex tb IIIC Db IP6X
EC Type Examination Certificate Number:
IBExU07ATEX1147 U
IECEx IBE09.0018U
The following European and International standards apply to this document
along with any applicable local regulations.
IEC 60079-0:2007-10 / EN 60079-0:2009
IEC 60079-7:2006-07 / EN 60079-7:2007
IEC 60079-11:2006 / EN 60079-11:2007
IEC 60079-31:2008 / EN 60079-31:2009
Stainless Steel 316L/1.4404
-60 °C ... +100 °C (+120 °C on request)
IP 66 according to DIN EN 60529
3