Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

WAVE
CONTROL
Spannungsüberwachungsmodul
WAVE
CONTROL
Voltage - monitoring module
WAVE
CONTROL
Module de contrôle de tension
VMA Vac
VMA Vac
VMA Vac
Beipackinformation
Operating instructions
Notice d'utilisation
4288400000/04/10.14
1
9
17

Publicité

Table des Matières
loading

Sommaire des Matières pour Weidmüller WAVECONTROL WAS2 VMA Vac

  • Page 1 Beipackinformation Operating instructions Notice d’utilisation WAVE VMA Vac CONTROL Spannungsüberwachungsmodul WAVE VMA Vac CONTROL Voltage - monitoring module WAVE VMA Vac CONTROL Module de contrôle de tension 4288400000/04/10.14...
  • Page 3 WAVE VMA Vac CONTROL Spannungsüberwachungsmodul Best.-Nr. Schraubanschluss WAS2 VMA Vac 8581220000 Zugfederanschluss WAZ2 VMA Vac 8581230000 Lesen Sie diese Beipackinformation bevor Sie das Produkt installieren und heben Sie diese für weitere Informationen auf.
  • Page 4 Allgemeine Hinweise Achtung! Das Spannungsüberwachungsmodul der Reihe WAVE CONTROL darf nur von qualifizier tem Fachpersonal installiert werden. Erst nach der fachgerechten Installation darf das Gerät mit Hilfsener- gie versorgt werden. Während des Betriebs darf keine Be- reichsumschaltung vorgenommen werden, da hierbei berüh- rungsgefähr liche Teile offen liegen.
  • Page 5: Gerät Öffnen

    Konfigurierung des Gerätes 3.1 Hilfsmittel Zum Einstellen des Gerätes und zum Anschluss der Leitungen an die Klemmen wird ein Schraubendreher mit einer Klingenbreite von 2,5 mm benötigt. 3.2 Gerät öffnen Stecker abziehen. Durch leichten Druck den Verschluss auf beiden Seiten des Gehäuses entriegeln (1), Gehäuseoberteil und Elektronik herausziehen (2).
  • Page 6 Auswahl des Eingangs Anschlussbelegung Eingang 0...30 Vac 0...70 Vac 0...130 Vac 0...250 Vac 0...450 Vac Auswahl des Ausgangs Anschlussbelegung Ausgang GND 1 U / I 0...10 V 0...20 mA 4...20 mA Umschaltung des Stromausgangs Ausgang 0...20 mA 4...20 mA 1= ein 0= aus...
  • Page 7: Montage

    3.4 Applikation 230 Vac 24 Vdc 10 11 Montage Das Spannungsüberwachungsmodul wird auf TS 35 Normschienen aufgerastet.
  • Page 8: Technische Daten

    Der elektrische Anschluss 11 12 Klemmenbelegung 1 Eingang 0 V- Bezugspotential 2 30 Vac 3 70 Vac 4 130 Vac 5 250 Vac 6 450 Vac 7 Spannungsausgang 0...10 V 8 Stromausgang 0/4...20 mA 9 Ausgang 0 V- Bezugspotential GND 1 10 Versorgungsspannung + 24 Vdc (querverbunden) 11 Versorgungsspannung 0 V GND 2 (querverbunden) 12 nicht belegt...
  • Page 9 Abmessungen in mm 92,4 Querverbindungen für Spannungsversorgung 24 Vdc...
  • Page 10 Zubehör (Querverbindung) Bezeichnung Best.-Nr. ZQV 2,5 N/2 gelb 1693800000 ZQV 2,5 N/2 rot 1717900000 ZQV 2,5 N/2 blau 1717990000 ZQV 2,5 N/2 schwarz 1718080000 Verbindermarkierer Bezeichnung Best.-Nr. WS 10/5 Multicard für Plotterbeschriftung 1635010000 WS 10/5 Neutral 1060860000 Hinweise zur CE-Kennzeichnung Das Spannungsüberwachungemodul VMA Vac trägt das CE-Zeichen und erfüllt die Anforderungen der EU-Richtlinien 2004/108/EG "Elektro - mag ne tis c h e Verträglichkeit"...
  • Page 11 WAVECONTROL VMA Vac Voltage - monitoring module Type Cat. No. Screw connection WAS2 VMA Vac 8581220000 Tension clamp connection WAZ2 VMA Vac 8581230000 Please read these instructions before using the product and retain for future information.
  • Page 12 General instructions Warning! Voltage-monitoring modules from the WAVECONTROL range should only be installed by qualified staff. Be sure not to connect the unit to power supply before appropriate installation. Do not select ranges during operation, because live parts are exposed during this process. Be sure to observe the national regulations for installation and selection of cables.
  • Page 13: Configuration

    Configuration 3.1 Equipment A screwdriver with a width of 2.5 mm is required to adjust the unit and to connect the wires to the terminals. 3.2 Opening the unit Disconnect the plugs. Disengage the top part of the housing by carefully pressing the latches on both sides (1).
  • Page 14 Selecting the input Wiring diagram Input 0...30 Vac 0...70 Vac 0...130 Vac 0...250 Vac 0...450 Vac Selecting the output Wiring diagram Output GND 1 U / I 0...10 V 0...20 mA 4...20 mA Switching the current output Output 0...20 mA 4...20 mA 1 = on 0 = off...
  • Page 15 3.4 Application 230 Vac 24 Vdc 10 11 Mounting The analogue signal isolators are mounted on standard TS 35 rails.
  • Page 16: Technical Data

    Electrical connection 11 12 Terminal assignments 1 Input 0 V - reference potential 2 30 Vac 3 70 Vac 4 130 Vac 5 250 Vac 6 450 Vac 7 Voltage output 0...10 V 8 Current output 0/4...20mA 9 Output 0 V- reference potential GND 1 10 Power supply + 24 Vdc (cross-connected) 11 Power supply 0 V GND 2 (cross-connected) 12 not assigned...
  • Page 17 Dimensions in mm 92.4 Cross-connections power supply 24 Vdc...
  • Page 18 Accessories (cross-connection) Designation Cat. No. ZQV 2,5 N/2 yellow 1693800000 ZQV 2,5 N/2 red 1717900000 ZQV 2,5 N/2 blue 1717990000 ZQV 2,5 N/2 black 1718080000 Connection markers Designation Cat. No. WS 10/5 Multicard for plotter marking 1635010000 WS 10/5 Neutral 1060860000 Notes on CE marking The WAS5/WAZ5 PRO Freq.
  • Page 19: Références

    WAVE VMA Vac CONTROL Module de contrôle de tension Type Références Raccordement vissé WAS2 VMA Vac 8581220000 Raccordement à ressort WAZ2 VMA Vac 8581230000 Veuillez lire la notice jointe avant d'installer le produit et conservez-là pour consultation ultérieure.
  • Page 20 Indications généralés Attention! Le module de contrôle de tension de la gamme WAVECON- TROL ne doit être installé que par un personnel qualifié. L'équi- pement ne doit être alimenté en énergie auxiliaire qu'après in- stallation dans les règles de l'art. Ne pas tenter de changer de plage pendant le fonctionnement, des pièces dangereuses par contact direct sont en effet accessibles.
  • Page 21: Accessoires

    Configuration 3.1 Accessoires Le raccordement des conducteurs sur les bornes nécessite un tournevis plat de 2,5 mm de largeur. 3.2 Ouverture de l’appareil Retirer les fiches. Presser légèrement sur les deux languettes (1) pour déverrouiller la partie supérieure du boîtier. On peut ainsi sortir la partie supérieure et l’électronique jusqu’à...
  • Page 22 Sélection de l'entrée Brochage Entrée 0...30 Vac 0...70 Vac 0...130 Vac 0...250 Vac 0...450 Vac Sélection de la sortie Brochage Sortie GND 1 U / I 0...10 V 0...20 mA 4...20 mA Commutation de la sortie courant Sortie 0...20 mA 4...20 mA 1 = activé...
  • Page 23 3.4 Application 230 Vac 24 Vdc 10 11 Montage Les séparateurs sont encliquetés sur des rails de norme TS 35.
  • Page 24: Le Raccordement Électrique Brochage 10

    Le raccordement électrique 11 12 Brochage 1 Entrée 0 V – masse 2 30 Vac 3 70 Vac 4 130 Vac 5 250 Vac 6 450 Vac 7 Sortie tension 0...10 V 8 Sortie courant 0/4...20 mA 9 Sortie 0 V – masse GND 1 10 Alimentation + 24 Vdc (connexion transversale) 11 Alimentation 0 V GND 2 (connexion transversale) 12 Non connectée...
  • Page 25 Dimensions en mm 92.4 Connexion transversale d’alimentation en tension 24 Vdc...
  • Page 26 Accessoires (connexion transversale) Désignation Réf. ZQV 2,5 N/2 jaune 1693800000 ZQV 2,5 N/2 rouge 1717900000 ZQV 2,5 N/2 bleu 1717990000 ZQV 2,5 N/2 noir 1718080000 Repère de connecteur Désignation Réf. WS 10/5 Multicarte pour libellés de table traçante 1635010000 WS 10/5 Neutre 1060860000 Remarques concernant le marquage CE Les séparateurs de signaux analoqiques WAS5/WAZ5 PRO Freq.

Ce manuel est également adapté pour:

Wavecontrol waz2 vma vac85812200008581230000

Table des Matières