DISPLAY
Over pushing stroke: if you enable this function, at every OPEN pulse the leaf on which the electric lock is installed starts its clos-
ing movement for a few seconds. This facilitate release of the electric lock.
F0
Disabled
F1
Enabled
Courtesy light/ Flashing lamp: with this parameter, you can select the type of output from the LAMP - LAMP terminals, selecting
from flashing lamp and courtesy light. IMPORTANT: Maximum load of terminals: 24 V
G0
Flashing lamp
G1
Courtesy light (active for about 90 seconds)
Slow-down point percentage: this parameter is used to set the length of the slowed down section, selecting it from the two
fixed values.
H0
40% of maximum memory-stored opening
H1
20% of maximum memory-stored opening
Speed during slowed-down phase: this parameter is used to set motor speed during the slowed down phase, selecting it from
the two values
i0
High
i1
Low
Operation with travel limit device: if you activate this function, you must use both travel limit devices, both at opening and
closing, on both motors (in case of two-motor applications).
Operation without travel limit device or with intermediate situations (only one travel limit device installed or a travel
L0
limit device on one of the two motors)
L1
Operation with opening and closing travel limit device and on all installed motors.
Number of motors: use this parameter to select the type of gate
M1
Single-leaf gate, only one motor connected
M2
Double-leaf gate, two motors connected
Pre-flashing at closure: if this function is activated before the closing phase, the flashing lamp pre-flashes to indicate that the
gate is about to move. Pre-flashing time is about 1.5 seconds and cannot be modified
n0
Pre-flashing excluded
n1
Pre-flashing ON
Immediate closure: if this function is activated, when the gate is open during a pause, and therefore with Automatic, Automatic
step-by-step or condominium logics, when one transits in front of the photocells active during closure or during opening and
closure, the gate closes immediately, without waiting for the programmed pause time to elapse.
o0
Immediate closure disabled
o1
Immediate closure enabled
Immediate closure/timer command: this function enables you to command immediate closure of the gate or to close it with
the OPEN A total opening command. This function is only active in combination with function logics with automatic closure of
the gate (Automatic, Ste-by-step Automatic and Condo).
Immediate closure: when the gate is open during a pause given with the OPEN A command, the gate begins the
P0
closing manoeuvre without waiting for pause time to elapse
Timer Function: when the gate is open during a pause, with a single impulse of the OPEN A command, the control
unit restarts counting the pause time before reclosing. If you keep pressing the OPEN A command, the pause time
P1
count stops and the gate stays open until the OPEN A command is active. When you release the command, the
gate recloses when pause time has elapsed
Before you begin programming, select the type of operation for the control unit: with or without encoder and any extra
travel distance (see paragraph 7).
During the programming procedure, the control unit memory-stores the mechanical contact points during opening, closing
and any pause time before re-closing.
1.
Release the gearmotors, locate the leaves at half-open point, and re-lock the operators.
2.
Power up the control unit and check if value "--" is shown on the display.
3.
Press and hold down key P2 until the display shows the first parameter and relevant value.
BRAIN 03 / BRAIN 04