Status
The service indicator lights red.
The service indicator blinks red.
Note
Bring the product to Hilti Service in good time. This will help to ensure
that it's always ready for use.
3.6 Active Vibration Reduction (AVR)
The breaker is equipped with an Active Vibration Reduction (AVR) system,
which reduces vibration significantly.
3.7 Items supplied
Breaker, operating instructions with bag to attach to the transport trolley,
grease.
The transport trolley is available as an accessory.
Note
You can find other system products approved for your product at your
local Hilti Center or online at: www.hilti.com
4 Technical data
4.1 Breaker
When powered by a generator or transformer, the generator or transformer's
power output must be at least twice the rated input power shown on the rating
plate of the power tool. The operating voltage of the transformer or generator
must always be within +5% and -15% of the rated voltage of the power tool.
The information given applies to a rated voltage of 120 V. The data may vary
in the event of deviations from the rated voltage and for country-specific
versions. Please refer to the power tool's type identification plate for details
of its voltage, frequency, current and input power ratings.
Rated current input
Weight
Single impact energy
Printed: 16.02.2017 | Doc-Nr: PUB / 5070870 / 000 / 05
Meaning
• End of service interval – servicing
is due.
• A fault has occurred in the tool.
• Protection against overheating
• The voltage provided by the
electric supply is too high.
TE 3000AVR
15 A
65.9 lb
(29.9 kg)
68 J
English
7