INDEX
Air Supply
Chimney Draught
Functions
Fresh Air Supply
6. Make up the fire for the first time
Door
Ashes
EC CONFORMITY DECLARATION
Date of issue: 20.09.2008
Conformity Declaration issued by:
Company name :
Address :
Postal :
Country :
Phone :
Fax :
Web :
E-mail :
Identification:
Product type:
Stove type:
Fuel type:
Flue gas mean temperature:
CO content at 13 % O
:
2
OGC content at nominal effect:
Nominal thermal output:
Energy efficiency at 8,7 kW:
Minimum requirement for draft:
Safety measures:
Minimum distance to combustible
materials:
Country
Classification
EUR
Intermittent
NO
Class II
General Manager, Nordpeis AS
10
10
Nordpeis AS
Gjellebekkstubben 9/11
N-3420 Lierskogen
Norway
(+47) 32 24 47 00
(+47) 32 24 47 11
www.nordpeis.no
post@nordpeis.no
Nordpeis TRIO
SINTEF 110-0301
Stove room heater
Welded iron stove burning solid fuel
Firewood only, see manual
303 ºC
0,07 %
141 mg/Nm
3
8,7 kW
70,4 %
14-25 Pa
Must be placed according to the manual
400 mm side, 150 mm back and 300 mm
corner
Standard
Approved by
SP Technical Research
EN 13240:2001
Institute of Sweden
NS 3059
NS 3058-1
SINTEF NBL
NS 3058-2
Stian Varre
Test reports:
SINTEF NBL 102042.48
SINTEF NBL
Tiller bru, Tiller N-7465 Trondheim, Norway

1. Prior to assembling the stove

10
All our stoves are tested according to the latest
10
European requirements and also to the Norwegian
10
SINTEF standard, which includes particle tests.
Several European countries however have individual
11
rules for installation of stoves, inserts and fireplaces.
11
You as a client are totally responsible for the fulfilling
of these local rules concerning the installation in
11
your region/ country. Nordpeis (Northstar) is not
11
responsible regarding correct installation. You should
11
check local regulations concerning: distance from
11
stove to combustible/flammable materials, insulation
11
materials/requirements between stove and back wall,
11
size of floor plates in front of stove if required, fluepipe
connection between stove and chimney and insulation
12
requirements if fluepipe goes through flammable wall
12
such as a wood wall.
12
12
Air Supply
12
A set for fresh air supply is available as an accessory,
12
and will ensure that ventilation systems, kitchen fans
and other factors that can create a downdraught in
13
the room of the stove affect less the air supply to the
13
stove. Insufficient air supply can cause downdraught
13
and thereby low combustion efficiency and the
13
problems that this entails: soot stains on the glass,
13
inefficient use of the wood and a soot deposits in the
14
chimney.
15
Chimney Draught
The draught is firstly affected by the length and cross-
section of the chimney.
Recommended chimney height is at least 4 metres
from where the flue pipe is connected to the chimney,
with an internal diameter of 150-200 mm. At nominal
effect the draught should have a pressure of 14 to
25 Pascal. If necessary, contact a professional for
assistance.
The stove needs to be placed on a plate of non-
combustible material, e.g. concrete, steel or
similar. Flooring such as carpet, cork and similar
must be removed from under this plate.
For your own safety, comply with the assembly
instructions. All safety distances are minimum
distances. Installation of the stove must comply
with the rules and regulations of the country
where installed. Nordpeis AS is not responsible
for wrongly assembled stoves.