PROGRAMMING
Programming button functions
Esc
<
>
Display symbols key
The encoder is deactivated.
The [Impact test] function is on.
The operator detected an obstruction when the gate was moving to the right.
The operator detected an obstruction when the gate was moving to the left.
2
The operator detected two obstructions when the gate was moving to the right.
The number on the display varies according to the number of obstructions detected.
When the maximum number of detected obstructions has been reached, the operator stops and an error message shows on the display.
2
The operator detected two obstructions when the gate was moving to the left.
The number on the display varies according to the number of obstructions detected.
When the maximum number of detected obstructions has been reached, the operator stops and an error message shows on the display.
There is at least one programmed timer.
A programmed timer is running.
With the timer programmed for opening or partial opening, any given radio command will always allow opening. The wired commands
continue to operate normally.
SLAVE
The SLAVE operator is in paired mode.

Getting started

Once the electrical connections have been made, proceed with commissioning. Only skilled and qualified staff may perform this operation.
Make sure that there are no obstacles in the way.
Power up the device and follow the instructions on the display.
Start programming following the wizard.
If this is not the first time the board is being switched on, go to the menu Configuration > Wizard. Follow the indications shown on the display.
Complete programming and check the warning and safety devices are working properly.
After powering up the system, the first manoeuvre is always to open the gate Wait for the manoeuvre to be completed.
Press the ESC button or STOP button immediately in the event of any faults, malfunctions, strange noises or vibrations, or unexpected behaviour in the
system.
Perform the first manoeuvre where you can see the gate in motion and with the photocells active, including where remotely controlled.
If CALIBRATION REQUIRED appears on the display, you must calibrate the travel. The panel will not accept motion commands, except for the motor test.
1
ESC button
The ESC button is used to perform the operations described below.
Exit the menu
Delete the changes
Go back to the previous screen
Stop the operator
2
< > buttons
The <> buttons are used to perform the operations described below.
Navigate the menu
Increase or decrease values
Ent
Open or close the operator
ENTER button
3
The ENTER button is used to perform the operations described below.
Access menus
Confirm choice