IECEx-installation drawing 5343QI01-V3R0
For safe installation of 5343B the following must be observed.
The module shall only be installed by qualified personnel who
are familiar with the national and international laws, directives
and standards that apply to this area. Year of manufacture can
be taken from the first two digits in the serial number.
Certificate
Marking
Standards
Hazardous area
Zone 0, 1, 2, 21, 22
Terminal: 3,4,6
Uo: 30 VDC
Io: 8 mA
Po: 60 mW
Lo: 35 mH
Co: 66 nF
IECEx DEK 20.0062X
Ex ia IIC T6...T4 Ga
Ex ia IIIC Db
Ex ia I Ma
IEC 60079-0: 2017, IEC 60079-11: 2011
6
4
5343B
3
Terminal: 1,2
Ui: 30 VDC
Ii: 120 mA
Pi: 0.84 W or 0.75 W
Li: 10 μH
Ci: 1.0 nF
5343V110-FR
Non Hazardous Area
+
1
-
2
Barrier
17