Caracteristiques Techniques; Technical Data - Profroid GRS Serie Mode D'emploi

Table des Matières

Publicité

CARACTERISTIQUES TECHNIQUES

TECHNICAL DATA

appLIcaTIoN MoYeNNe TeMperaTure
grs
Puissance frigorifique nominale
Nominal cooling capacity
Puissance absorbée nominale
Nominal input power
Nombre
Compresseur
Number
Compressor
Type
Type
Niveau sonore
Sound level
Tension d'alimentation
Power supply
Intensités
Id
totales
Imax
Total current
Volume réservoir
Std/Opt
Receiver volume
DESP 97/23/CE Cat. Risque
PED 97/23/EC Risk Cat.
Aspiration
Suction
Refoulement
Raccordements
Discharge
Connections
Entrée réservoir
Receiver inlet
Sortie réservoir
Receiver outlet
Fig.
Longueur
Dimensions
Lenght
Dimensions
Largeur
Width
Hauteur
Height
Poids
Weight
430
Fig. 3
(1) Conditions nominales au R404A : Température d'évaporation -10°C. Température de condensation +45°C.
Surchauffe 20K. Sous-refroidissement 0K.
(2) Les niveaux de pression acoustique (en dBA à 10 mètres) sont indiqués en champ libre.
Le fonctionnement à un régime différent de ces conditions nominales peut conduire à des résultats différents.
Les résultats obtenus sur le lieu de l'installation peuvent être différents par rapport aux valeurs du catalogue, du
fait de phénomènes de réflexion (présence de mur, etc ...).
L'affaiblissement du niveau sonore en fonction de la distance est théorique et les phénomènes de réflexion et de
résonnance peuvent modifier le résultat, soit au niveau global pondéré, soit sur certaines fréquences.
(3) Intensité de démarrage (courant rotor bloqué).
(4) Intensité max. de fonctionnement.
4
ZB19 Z ZB21 Z ZB26 Z ZB29 Z ZB38 Z ZB45 Z ZB48 Z ZB57 Z ZB66 Z ZB76 Z ZB95 Z ZB114 Z
(1)
kW
4,0
4,9
(1)
kW
2,1
2,5
1
1
ZB19
ZB21
ZB26
KCE TFD
KCE TFD
KCE TFD
(2) dB(A)
38
41
(3)
A
32
40
(4)
A
6,5
7,2
dm³
7,1/14
7,1/14
7,1/14
Std/Opt
I/II
I/II
inch
7/8"
7/8"
7/8"
inch
5/8"
5/8"
5/8"
inch
1/2"
1/2"
1/2"
inch
3/8"
3/8"
3/8"
1/2
1/2
mm
550
550
mm
430
430
mm
500
500
kg
47
49
Fig. 1
40
550
510
5,6
6,6
8,2
9,7
2,9
3,3
4,2
4,8
1
1
1
1
ZB29
ZB38
ZB45
KCE TFD
KCE TFD
KCE TFD
KCE TFD
41
41
44
44
400V/~3/50Hz
46
50
66
74
8,9
10,0
10,7
12,8
7,1/14
14/18
14/18
I/II
I/II
II
II
7/8"
7/8"
7/8"
5/8"
5/8"
5/8"
1/2"
7/8"
7/8"
3/8"
1/2"
1/2"
1/2
1/2
2
2
550
550
650
650
430
430
480
480
500
500
500
500
50
57
71
74
480
(1) Nominal capacities with R404A : Saturated suction temperature -10°C. Saturated discharge temperature +45°C.
Superheat 20K. Subcooling 0K.
(2) The sound presure levels (in dB(A) at 10 meters) are mentioned in free field.
Running the equipment in conditions differing from these nominal values may lead to different results.
The results obtained on the installation site may differ from those in this leaflet, due to sound reflections from
walls, etc.
The reduction of sound level as a function of distance is theoretical and sound reflection and resonance may
alter the results, either on total sound level or on certain frequencies.
(3) Locked Rotor current.
(4) Max. operating current.
meDIUm TemperATUre AppLICATIoN
11,5
12,8
14,6
17,2
5,7
6,3
7,1
8,1
1
1
1
ZB48
ZB57
ZB66
ZB76
KCE TFD
KCE TFD
KCE TFD
45
48
49
49
101
102
111
118
14,0
17,6
17,5
20,4
14/18
14/18
14/18
14/18
II
II
II
1"1/8
1"1/8
1"3/8
1"3/8
7/8"
7/8"
7/8"
7/8"
7/8"
7/8"
7/8"
7/8"
5/8"
5/8"
5/8"
5/8"
3
3
3
730
730
730
730
510
510
510
510
600
600
600
600
79
83
100
100
Fig. 2
730
20,9
24,8
10,5
12,6
1
1
1
ZB95
ZB114
KCE TFD
KCE TFD
50
54
140
174
28,2
33,3
18/24
18/24
II
II
II
1"3/8
1"5/8
7/8"
7/8"
7/8"
7/8"
5/8"
5/8"
3
3
3
730
730
510
510
600
600
110
110
650

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Grs zb19 zGrs zb21 zGrs zb26 zGrs zb29 zGrs zb38 zGrs zb45 z ... Afficher tout