Technical Data; General Data And Operating Conditions - Lenze EZN30110H030 Serie Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4

Technical data

General data and operating conditions

4
Technical data
4.1
General data and operating conditions
Mains data
Mains types
With grounded neutral (TT/TN systems)
Other mains types
Protection
Degree of protection
Insulation resistance
Leakage current
Ambient conditions
Temperature
Storage
Transport
Operation
Site altitude
Pollution
Vibration resistance
Mounting conditions
Mounting location
Mounting position
Mounting position
Free spaces
at the top
at the bottom
to the sides
34
All manuals and user guides at all-guides.com
Operation permitted without restrictions
Observe instructions for special measures in the
documentation for the basic device!
EN 60529
IP 20
EN 61800−5−1
Overvoltage category III
> 2000 m: Overvoltage category II
EN 61800−5−1
> 3.5 mA
−25 ... +60 °C
−25 ... +70 °C
−10 ... +55 °C
Current derating from +40 to +55 °C: 2.5 %/°C
0 ... 4000 m amsl
1000 ... 4000 m amsl: Current derating by 5 %/1000 m
EN 61800−5−1
Pollution degree 2
EN 50178; IEC
Acceleration−resistant up to 0.7 g
61800−5−1;
Germanischer Lloyd,
general conditions
In the control cabinet
Directly above the standard device
Vertical, mains connection on top
> 100 mm
determined by the standard device
> 50 mm
l
Not in the wire range of
the terminals
Observe regulations and
safety instructions!
EDKZNXXXX−002 DE/EN/FR 3.0

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ezn30080h042 serieEzn30055h060 serieEzn30037h090 serieEzn30030h110 serieGlobal drive ezn30110h030 serieGlobal drive ezn30080h042 serie ... Afficher tout

Table des Matières