Xylem Rule Mate Manuel D'utilisation page 3

Masquer les pouces Voir aussi pour Rule Mate:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
RuleMate Intelligence
RuleMate bilge pumps have built-in programming that can sense when the pump
is running but not pumping water to protect the pump, vessel, and the vessel's
batteries. If debris fouls the sensor or the pump becomes air-bound, the pump will
stop running and begin to "check" for water every 2-1/2 minutes. Once the debris
is removed, the pump will revert to its normal operation, turning on when the
water reaches approximately 2-1/2" (63.5 mm) and shutting off at 5/8" (15.87 mm).
Our RuleMate bilge pumps contain a fail-safe back-up program that measures
the amount of work the motor is performing and the length of time the motor is
running. If debris, such as a wet paper towel or leaves, became lodged against the
pump, it could "trick" the pump into thinking water remained in the bilge which
could deplete the vessel's battery.
If the circuit board senses the motor is running but doing little work (not pumping
water) for longer than fifteen seconds, the pump will enter into a cycling mode in
the same fashion as the computerized pumps. The pump will sense water every
2-1/2 minutes and if it senses water, it will continue to run until the water has been
removed from the bilge.
After the debris is removed, the pump will automatically revert to the level sensing mode.
CAUTION: Disconnect power from the system before working on the
unit to avoid personal injury, damage to the surrounding environment
and/or damage to the unit.
CAUTION: Always install proper fuse size to prevent damage to product
should a short occur. Failure to install proper fuse could increase risk of pump
malfunction, potentially resulting in personal injury and/or fire hazard.
CAUTION: Keep all wire connections above the highest water level.
Wires must be joined with butt connectors and a marine grade sealant to
prevent wire corrosion.
4
Automatic Pump Wiring — 3 Wires
3 Position
Panel Switch
Brown with white stripe
Brown
PUMP
Black
Constant Auto/
Manual Override
PUMP
Black
Constant Auto/
No Manual Override
PUMP
Black
On 12 volt pump: Minimum voltage of 10.5 volts required.
On 24 volt pump: Minimum voltage of 21 volts required.
Panel
Switch
MANUAL
POWER
AUTO
Fuse
Battery
MANUAL
Brown with white stripe
Brown
POWER
Fuse
Battery
Brown with white stripe
Terminate with
Brown
waterproof sealant
Fuse
Battery
5

Publicité

Table des Matières
loading

Table des Matières