In-line blower
To minimize noise in the kitchen, these blowers are
mounted along the duct line anywhere between the
kitchen and the exterior wall. If there is easy access to duct
line (in an attic, for example), this may be an appealing
option.
inches (mm)
12⅛"
(308)
ø
9⅞"
(251)
Remote and in-line blower motor wire connection
1. Remove junction box channel covering the wires.
2. Remove one circular knockout.
3. Route the blower motor's plug connector to the hood.
Connect the blower's harness to the hood harness.
4. Route the blower harness through the self-locking
clip.
Electrical wire connection
Connecting the electrical wire
1. Run a 120V AC, 15A circuit power cable from the
service panel through the strain relief. ( See "Hanging
the chimney wall hood" on page 13 . .)
12"
(305)
⅞" (22)
19⅛"
(486)
1¾"
(44)
12⅞"
(327)
14⅜"
(365)
2. Connect black wire to power supply black wire, white
wire to power supply white wire and green wire to
green wire or bare wire.
Green to green
or bare wire
3. Place all wiring connections inside the junction box
channel. Reinstall on the top plate. Ensure that the
wires are secure and that no wires are pinched.
EXTNCB25W 25 ft. remote and in-line
blower extension cable (optional)
To connect the extension cable to the hood
1. Route the hood's internal blower harness through the
strain relief.
2. Connect the 25 ft. extension cable to the blower
harness outside the hood.
1
1
Connects to the hood
2
Connects to a remote or in-line blower
NOTE: Cutting of the connector will void the warranty of
the appliance.
The blower extension cable is compatible with the
following in-line and remote blowers:
Blower
Remote blower
Remote blower
In-line blower
In-line blower
White to white
Black to black
2
Model
VTR2FZ
VTR1FZ
VTI1FZ
VTI2FZ
16