Hood Transition

Assembly of the Transition
1. A minimum height clearance of 7-7/16'' (188 mm) is
needed above the hood for transition mounting.
7/ 16
7
7
7
"
(188)
(188)
(188)
20 ¼"
20 ¼"
20 ¼"
(514)
(514)
(514)
11/
11/
11/
12
12
12
"
16
16
16
(326)
(326)
(326)
2. Align mounting holes at base of transition over the
mounting holes of the 1/2'' (13 mm) flange located at
the top of the hood (see Figure 4).
3. Fasten transition to hood using four (4) 1/4'' (6 mm)
sheet metal screws included with hood (see Figure 4).
4. Seal connection between transition and hood with
aluminum tape (Figure 4). DO NOT use duct tape.
Ensure that the connection is completely sealed.
5. Remove tape holding damper closed.
Installation Instructions
inches (millimeters)
Figure 3: Transition Height
Figure 4: Transition Connection

Electrical Requirements

The unit requires a 120V AC, 60Hz. 15A branch circuit. The
hood should be connected to its own circuit.
The hood should be hard-wired and properly grounded
according to relevant regulations. Route the wiring as close
to the appliance as possible and in an accessible location.
When connected to a GFCI-protected supply,
THERMADOR PROFESSIONAL
suitable for use in damp locations that are protected from
outside weather conditions and not subject to saturation
with water and other liquids, but can be subject to
moderate degrees of moisture (such as an outdoor covered
patio or lanai area). Refer to local codes, NEC/CEC, and or
the Authority Having Jurisdiction (AHJ) for additional
information.
Check your local building codes for proper method of
installation. In the U.S., if there are no applicable local
codes, this unit should be installed in accordance with the
National Electric Code ANSI/NFPA No. 70, Current Issue.
In Canada, installation must be in accordance with the CAN
1- B149.1 and .2 - Installation Codes for Gas Burning
Appliances and/or local codes.
The appliance must be grounded. In the event of an
electrical short circuit, grounding reduces the risk of electric
shock by providing a wire that allows the electric current to
escape.
WARNING
The appliance must be grounded.

Electrical Data

Data, including the model and serial number, is located on
the product data rating plate inside the appliance, visible
after removal of the filter frame (see Figure 31 on page 20).
®