Hydro Unit
10
Night Setback
Hydro 2 Way
12
Valve Operation
Control
Hydro 3 Way
13
Diverting Valve
Operation Control
2 Zone Mixing
14
Valve Drive Time
Boiler/Heat Pump
15
Synchronisation
Maximum
Operation Time Of
16
Hot Water Heat
Pump
17
Cooling Operation
Remote Controller
18
Indication
CDU Night Time
19
Low Noise
Operation
20
Alarm Tone
E-Stop Switch
21
Logic
35-EN
FC Description
Change Setback Temperature
Zone selection 0=Zone 1 & 2;
1= Zone 1 Only
Start Time (Hour)
End Time (Hour)
Cooling 2 Way Valve -
Operation Logic 0=Activated
during cooling; 1=Not
activated during cooling
3 Way Diverting Valve
Operation Logic 0=Activated
during hot water operation;
1=not activated during hot
water operation
Specified Drive Time for
Mixing Valve (x10sec)
Mixing valve OFF (control time
- mins)
External Boiler/Heat Pump
Synchronisation
0=Synchronised; 1=Not
synchronised
Maximum Heat Pump
Operation Time In Hot Water
Operation Priority Mode
(minutes)
0=Cooloing & Heating
Operation; 1=Heating Only
Operation
24h or 12h Time Indication 0=
24h; 1=12h
Low Noise Operation
0=Invalid; 1=Valid
Start Time (Hour)
End Time (Hour)
Tone Switching 0=OFF; 1=ON
0 = Contacts low > high
system stop. System restart
with remote controller
1 = Contacts high > low
system stop. System restart
with remote controller
2 = Contacts high > low
system stop. Contacts low >
high system restart
3 = Contacts low > high
system stop. Contacts low >
high (second time) system
restart
0 = Restart hot water and
heating
1 = Restart in the mode when
stopping
2 = Restart heating
3 = Restart hot water
4 = Tempo control 1; without
heater
5 = Tempo control 2; without
HP and heater
Location & FC
Number
Hydro
RC
Range
26
–
3~20°C
58
–
0~1
–
0E
0~23
–
0F
0~23
3C
–
0~1
54
–
0~1
0C
–
3~24
59
–
1~30
3E
–
0~1
07
–
1~120
02
–
0~1
–
05
0~1
–
09
0~1
–
0A
0~23
–
0B
0~23
–
11
0~1
52
–
0~3
61
–
0~5
– 36 –
Installation Manual
After
Change
Default
Commissioning
1
5
1
22
06
0
0
6
4
0
30
1
0
0
22
06
1
0
0
Change
2