24
Operation
EN
Pon
PoF
SoS
Crt
USER MANUAL | MANUEL D'UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
When the method is selected, the welding time is set.
Welding Time
• 0.2 - 9.9 sn.
Setting Range
No welding period is set when the method is selected.
Blank Time
• 0.0 - 9.9 sec.
Setting Range
Soft start setting is made.
Soft Start
• On - Off
Setting Range
When starting to weld, the wire speed gradually increases from low speed to the set speed.
In this way, knocks and splashes at the beginning of the welding are prevented.
Crater function setting is made.
Crater
• On - Off
Setting Range
It is the filling process to prevent cracks that will occur at the end of welding. When the
crater is active, the welding current is reduced with a certain linearity at the end of the
welding and the welding ends.
COMPACT SMART SERIES / KOMPAKT SMART SERİSİ
www.magmaweld.com