Installation
Structural Rough-Ins
Mounting for standard ADA and TAS height shown.
Areas highlighted in gray require sufficient backing
compliant with local building codes.
A
C
33½"
(851mm)
Ref. Rim
Height
32"
(813mm)
26½"
(673mm)
CODE
A
Install (1) ³⁄₈" wall anchor with a minimum pull-out force of 1,000 lbs. per local codes at locations shown
B
Install (2) wall anchors per bracket with a minimum pull-out force of 100 lbs. per local codes at locations shown
C
Rim Height
Bradley • 215-1816 Rev. D; ECN 16-08-008
Wall Bracket
10½"
(267mm)
30"
(762mm)
bottom
of wall
bracket to
finished
floor
34¾"
(882mm)
39"
(991mm)
Provide structural backing compliant with local building codes.
Vertical Height Adjustments
33½"
No Adjustment
30½"
Subtract 3"
26"
Subtract 7½"
36½" (927mm)
C L
B
B
12¼"
12¼"
(311mm)
(311mm)
DESCRIPTION
Standard, ADA & TAS
Juvenile, ADA & TAS
Secure bracket to wall using min.
(2) ³⁄₈" anchor bolts to the left of
C/L and min. (2) ³⁄₈" anchor bolts
to the right of C/L. The (2) anchor
bolts to the right of C/L must be
min. 16" apart from the anchor bolts
to the left of C/L. When mounting
is complete, check to ensure the
bracket is level. See Step 1: Bracket
Mounting for more information.
Trap Cover Bracket
(2x)
34¾"
(883mm)
39"
(991mm)
Fixture Style
Junior
5/20/2016
ELX-3
A
C
32"
(813mm)
26½"
(673mm)
QTY.
2
4
2
7