Operation
The hood is fitted with a control panel with aspiration speed
selection control and a light switch to control cooking area
lights.
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
Maintenance
ATTENTION! Before performing any maintenance operation,
isolate the hood from the electrical supply by switching off at
the connector and removing the connector fuse.
Or if the appliance has been connected through a plug and
socket, then the plug must be removed from the socket.
Cleaning
The cooker hood should be cleaned regularly (at least with the
same frequency with which you carry out maintenance of the
fat filters) internally and externally. Clean using the cloth
dampened with neutral liquid detergent. Do not use abrasive
products. DO NOT USE ALCOHOL!
WARNING: Failure to carry out the basic cleaning
recommendations of the cooker hood and replacement of the
filters may cause fire risks.
Therefore, we recommend oserving these instructions.
The manufacturer declines all responsibility for any damage to
the motor or any fire damage linked to inappropriate
maintenance or failure to observe the above safety
recommendations.
Grease filter
Traps cooking grease particles.
The grease filter must be cleaned once a month using non
aggressive detergents, either by hand or in the dishwasher,
which must be set to a low temperature and a short cycle.
When washed in a dishwasher, the grease filter may discolour
slightly, but this does not affect its filtering capacity.
To remove the grease filter, pull the spring release handle.
Fig. 1
Charcoal filter (filter version only)
It absorbs unpleasant odours caused by cooking.
The saturation of the charcoal filter occurs after more or less
prolonged use, depending on the type of cooking and the
regularity of cleaning of the grease filter.
In any case it is necessary to replace the cartridge at least
every four mounths.
The charcoal filter may NOT be washed or regenerated.
It may be one of the following types:
Circular filter – 2 pieces – with and without central handle –
Figs. 2-3):
They are placed at the ends of the motor, therefore proceed
rotating the carbon filters (or the central handle – Fig. 3)
anticlockwise until they detach.
Rectangular type - Fig. 4:
These are fixed to the cooker-hood structure.You should
unwind the screws that keep the carbon filters to the cooker-
hood.
To re-esemble proceed using the reverse of the above
procedure.
Replacing lamps
Disconnect the hood from the electricity.
Warning! Prior to touching the light bulbs ensure they are
cooled down.
Replacing lightbulbs 40W - Access the light compartment -
Remove the fixing screws of the light shield. Unscrew the
damaged light bulb and replace with an incandescent oval
light bulb with a maximum of 40W E14.
Replacing the halogen bulbs - Access the light compartment
– extract the lamp cover by levering it off with a small
screwdriver or similar tool.
Replace the damaged light bulb. Only use halogen bulbs of
20W max (G4), making sure you do not touch them with your
hands. Close the lamp cover (it will snap shut).
Fig. 5
If the lights do not work, make sure that the lamps are fitted
properly into their housings before you call for technical
assistance.