1. Release latches and remove power-head from recovery tank.
2. Ensure that the conductive, polyester filter assembly (#2, #3, #4, page 9)
is properly mounted inside the recovery tank. If not, refer to the instructions for
"Replacing the Main Filter" (page 6).
3. Place the power-head back on the recovery tank and fasten latches.
4. Attach the conductive hose to the suction
inlet on the recovery tank and attach the desired tool to the hose.
5. Perform a ground continuity test (see page 2) before using the machine.
WARNING: Operate this machine only on properly grounded electrical outlets.
MAKING ADJUSTMENTS TO CONTAINER GASKETS
If you suspect the gasket between the motor head and the filter
chamber is not sealing properly:
1. Loosen latch screws "A" and slide latch downward.
2. Tighten latch screws.
3. Turn on the unit and inspect the seal between the motor
head and filter chamber.
4. Replace the gasket if the seal continues to leak.
If you suspect the gasket between the filter chamber and the
collection can is not sealing properly:
1. Loosen the screws "A" that lock filter chamber "B" against
the vacuum structure.
2. Lower filter chamber "B" slightly and retighten screws "A".
3. Turn on the unit and inspect the seal between the filter
chamber and the collection can.
4. Replace the gasket if the seal continues to leak.
INSTRUCTIONS FOR USE
PREPARING THE MACHINE FOR DRY RECOVERY
PAGE 3