Safety
SAFETY INFORMATION
Use this pump only on a 115
volt circuit. Pump is equipped
Hazardous
voltage
with an approved 3-conduc-
tor cord and 3-prong, grounding-type
plug. To reduce the risk of electric shock,
connect it to a properly grounded,
grounding-type receptacle.
If circuit has a 2-prong receptacle, replace
it with a properly grounded 3-prong recep-
tacle installed in accordance with the
National Electrical Code and local codes
and ordinances.
Any extension cord used must be outdoor
grade, gauge 16 AWG or heavier, and not
more than 25' long.
Risk of fire or explosion if
used to pump flammable liquids or if used
in explosive atmospheres. Pump water
only with this pump. Pump is designed
to pump water at temperatures between
32°-77° F (0°-25° C) only.
Risk of electrical shock. Do
not allow the motor to get wet!
Risk of burns. During nor-
mal operation, motor will normally run hot
enough to burn you. Do not touch motor
when it is hot.
Do not operate the pump continuously at a
discharge pressure of more than 12 psi
(83 kPa) or discharge lift of more than
28' (8.5 M), as the motor will exceed the
normal safe operating temperature and
may heat to 180° - 190° F (82° C - 88° C).
NOTICE: This unit is not designed for appli-
cations involving salt water or brine! Use
with salt water or brine will void warranty.
2