E7: Pump Status Detection; Reading Out The Number Of Cleaning Cycles; Cleaning Cycles In 24 Hours - Oase ProfiClear Premium Compact-M EGC Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

- EN -
6.5.4

E7: Pump status detection

(deactivated for pumped system)
The pump status detection signals whether the pump is operating properly via the Er88 system
message. The status detection is deactivated in the default setting.
If the system message ER77 or ER88 is displayed, it is necessary to change the status detection manually.
Proceed as follows
1.
Menu
Press
several times until E7 appears in
the display.
2.
Menu
Keep
pressed for 5 s until the value 0 or
1 is indicated in the display.
3.
Menu
Press
to change the value.
6.6

Reading out the number of cleaning cycles

6.6.1

Cleaning cycles in 24 hours

Proceed as follows
Menu
Clean
Press
and
26
Information
 To cancel and exit the menu: Either wait for 10 s or press
 To cancel and exit the menu: Either wait for 5 s or press
Adjustable range: 0 or 1
 0: The pump status detection is deactivated.
 1: The pump status detection is activated.
Important: Ensure that the value is set to 0 (status detection deactivated).
 Cancel without saving and exit the menu: Press
Information
The sum of the automatic and time-dependent cleaning cycles is saved. The
for 5 s.
4-digit value is displayed in groups of two digits that appear in succession in
the display.
Example:
01-17: Represents 117 cleaning cycles
The number is repeated five times after an extended pause to make it
easier to read:
01-17---01-17---01-17---01-17---01-17
Note:
If the mains voltage is switched off, the counter is reset to 0.
Note:
Due to the self-test of the filter system very different values may be
displayed. The self-test monitors the automatic cleaning process. The test is
carried out continuously in a 2 × 24 hour cycle. The test is only active from a
water temperature >53.6 °F.
 First 24 hour cycle
 Second 24 hour cycle
 If at least one automatic cleaning process is detected, the cycle is
repeated after the cleaning process has finished.
 If no automatic cleaning process is detected, the second 24 hour cycle
starts once the first has finished.
 The time-dependent cleaning cycle is deactivated. This reduces the
number of cleaning cycles.
 If at least one automatic cleaning process is detected, the first 24 hour
cycle starts again once the cycle has finished.
 If no automatic cleaning process is detected, the system message Er22 is
triggered at the end of the cycle. The time-dependent cleaning cycle
starts again. If an automatic cleaning process is then detected, the first
24 hour cycle starts again. The system message Er22 is automatically
reset.
On|Off
Clean
or
.
On|Off
Clean
or
.
On|Off
Clean
or
.

Publicité

Table des Matières
loading

Table des Matières