11- IS THERE A PROBLEM ?
Problems
Water runs through the holes in the
soleplate.
White streaks come through the holes
in the soleplate.
Brown streaks come through the holes
in the soleplate and stain the linen.
The soleplate is dirty or brown and may
stain the linen.
There is little or no steam.
Steam escapes from the boiler cap.
Steam escapes under the appliance.
Never dismantle your iron : always take it to an Approved Service Centre.
HELPLINE
If you have any product problems or queries with your product, please telephone our
Customer Relations team on :
0845 602 1454 (UK) (Calls charged at local rate)
Consult our web site : www.tefal.co.uk
All manuals and user guides at all-guides.com
Possible causes
The boiler is too full.
The thermostat is not working :
the temperature is always too
low.
You are using the steam control
button before the iron is hot.
You are using the steam contol
button on too low a temperature.
The water has condensed in the
pipes because you are using steam ■from your ironing board until
for the first time or you have not
used it for some time.
Your boiler has a build-up of scale
because it is not rinsed out regularly. 10 uses. If your water is hard,
You are using chemical descaling
agents or additives in the water for
ironing.
You are ironing at too high a
temperature.
Your linen is not rinsed sufficiently
or you are using starch.
The boiler is empty
The boiler is not yet ready.
Cap screwed on incorrectly.
The seal on the cap is damaged.
The equipment is faulty.
Solutions
Do not fill the boiler right up to
the top.
Contact an Approved Service
Centre.
Wait for the thermostat light to
go out before activating the steam
control button.
Enure that the thermostat control
is set within the coloured zone.
Press the steam control button away
the iron produces steam.
Rinse out the boiler after every
increase the frequency.
Never add this type of product in
the boiler (see our recommenda-
tions regarding water to be used).
See our recommendations regarding
temperature control setting.
Always spray starch onto the reverse
side of the fabric to be ironed.
Fill the boiler.
After switching on, wait for the
steam indicator light to go out
(after 8 mins.).
Screw the cap back on.
Change the cap seal.
(Spare seals supplied with the
steam generator in the box).
Stop using the generator and
contact an Approved Service
Centre.