PROBLEM
The charger will
not turn on when
properly connected.
I cannot select a 6V
or 12V setting.

15. SPECIFICATIONS

Input Voltage ..................................................................120V AC @ 60Hz, .40A
Output Voltage .......................................6V or 12V, with Auto Voltage Detection
Output Current Rating ..........................................................1.5A @ 6V and 12V

16. BEFORE RETURNING FOR REPAIRS

For REPAIR OR RETURN, contact Customer Service at 1-800-621-5485.
DO NOT SHIP UNIT until you receive a RETURN MERCHANDISE
AUTHORIZATION (RMA) number from Customer Service at Schumacher
Electric Corporation.
POSSIBLE CAUSE
AC outlet is dead.
Poor electrical connection.
Battery is defective.
The charger is equipped with
Auto Voltage Detection, which
automatically detects the
voltage and charges the battery.
For information about troubleshooting,
contact customer service for assistance:
services@schumacherelectric.com
www.batterychargers.com
or call 1-800-621-5485
Monday-Friday 7:00
to 5:00
am
pm
• 13 •
REASON/SOLUTION
Check for open fuse or
circuit breaker supplying
AC outlet.
Check power cord and
extension cord for loose
fitting plug.
Have battery checked.
No problem; this is normal.