Inspection And Servicing Instructions; Bleeding The Air - Columbus McKinnon Silverline HWK KLS 0,5 Mode D'emploi

Table des Matières

Publicité

Hydraulic workshop crane SILVERLINE
English

Inspection and servicing instructions

Inspection intervals
Daily or before use
Quarterly
Every six month
Every year
Every 2 years
1)
e.g. by Pfaff-silberblau after-sales service
The service life of your crane is limited. Worn parts must be renewed in good time.
Hydraulic system
The hydraulic system is comprised of a cylinder pump unit with a built-in lowering valve, safety valve and built-
in overpressure and non-return valve.
Apart from the inspections required in accordance with the maintenance instructions and the stipulated oil
change, the hydraulic system should require little maintenance.
Before starting any maintenance or repair work on the hydraulic pump, always first make sure that it is not
under load (make it unpressurized).
Never use the hydraulic pump without oil!
To change the oil, the oil must be suctioned out of the oil tank.
After the oil has been changed it may be necessary, or whenever needed otherwise, to bleed the air from the
hydraulic system.
Only ever bleed air from the system when not under load.
Check the oil level!

Bleeding the air

Actuate the hydraulic system several times when not under
load (lift and lower).
Hydraulic system circuit
A) Pump
B) Oil filter
C) Pressure control valve
D) Lowering brake valve
E) Lowering valve
F) Non-return valve
H) Cylinder
technische Änderungen vorbehalten
Servicing and inspection work
Visual inspection of the operating elements and lifting tackle (hook, safety catch).
Check that the workshop crane is in proper working order.
Pin connections/fasteners.
Clean wheels, handles and lowering device.
Are there any leaks?
Grease all stud bearings
Check, clean and oil the load handling equipment.
Clean and oil moving parts.
If used infrequently, pump up the lifting pistons and move completely in again.
Check the oil level.
Check all parts of the crane for wear and replace any defective parts if necessary.
Check that the model plate is completely legible.
Have the annual test carried out by an expert
Change the oil.
design changes under reserve
F 09.02.136
1)
changements techniques sous réserve
14 / 32

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Silverline hwk kls 1,0

Table des Matières