Doseur de Fluide Haute Précision Ultimus V
Annexe B — Protocole RS-232 (suite)
2.6.3.3 Pressure Time Vacuum Read Command (continued)
The above text packet in hexadecimal format:
STX
1
0x02
0x31
0
0
0x30
0x30
2.6.3.4 Memory Location Read Command
This command returns the current memory location at which the dispenser is set. "D0" is the letter "D" followed by
the digit "0."
Client command and data: (STX) + 04 + UA-- + C6 + (ETX)
The above text packet in hexadecimal format:
STX
0
0x02
0x30
Return Format: D0ccc
ccc: The 3-digit memory location from 0–399.
EXAMPLE: If the current memory location is 001, the text packet received from the dispenser is:
(STX) + 05 + D0001 + 96 + (ETX)
The above text packet in hexadecimal format:
STX
0
0x02
0x30
66
www.nordsonefd.com/fr EFDEU-South@nordson.com
5
D
0
P
0x35
0x44
0x30
0x50
5
5
V
C
0x35
0x35
0x56
0x43
4
U
A
space space
0x34
0x55
0x41
0x20
5
D
0
0
0x35
0x44
0x30
0x30
+33 (0) 1 30 82 68 69 Les services et les points de vente des systèmes de dosage Nordson EFD sont présents dans le monde entier.
D
0
5
0
0x44
0x30
0x35
0x30
0
1
0
0
0x30
0x31
0x30
0x30
C
6
ETX
0x20
0x43
0x36
0x03
0
1
9
6
0x30
0x31
0x39
0x36
0
D
T
1
0x30
0x44
0x54
0x31
E
0
ETX
0x45
0x30
0x03
ETX
0x03