Set Trigger Value Command; Set The Real Time Clock Command - Nordson EFD Ultimus V Manuel Utilisateur

Masquer les pouces Voir aussi pour Ultimus V:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Annexe B — Protocole RS-232 (suite)

2.6.2.20 Set Trigger Value Command

This command downloads the 5-digit trigger value into the current memory location.
Client command and data: EQ--Tttttt
ttttt: Trigger Value. 00001–99999
EXAMPLE: If the trigger value is 1000, the text packet it: (STX) + 0A + EQ-- + T01000 + 74 + (ETX)
Length of this text packet: Decimal 10 or hexadecimal 0A
The above text packet in hexadecimal format:
STX
0
A
0x02
0x30
0x41
4
ETX
0x34
0x03

2.6.2.21 Set the Real Time Clock Command

This command sets the time for the real time clock on the dispenser.
Client command and data: EB--HhhMmmAMa
hh:
Hours. 0–23 for 24 hour format, 1–12 for 12 hour format
mm: Minutes. 0–59
a:
Hour format. 0 = AM, 1 = PM, 2 = 24 hour format
EXAMPLE: To set the time as 14:05 and the hour format to 24-Hour, the text packet is:
(STX) + 0D + EB-- + H14M05AM2 + A6 + (ETX)
Length of this text packet: Decimal 13 or hexadecimal 0D
The above text packet in hexadecimal format:
STX
0
D
0x02
0x30
0x44
M
2
A
0x4D
0x32
0x41
www.nordsonefd.com/fr EFDEU-South@nordson.com
E
Q
space space
0x45
0x51
0x20
0x20
E
B
space space
0x45
0x42
0x20
0x20
6
ETX
0x36
0x03
+33 (0) 1 30 82 68 69 Les services et les points de vente des systèmes de dosage Nordson EFD sont présents dans le monde entier.
Doseur de Fluide Haute Précision Ultimus V
T
0
1
0
0x54
0x30
0x31
0x30
H
1
4
M
0x48
0x31
0x34
0x4D
0
0
7
0x30
0x30
0x37
0
5
A
0x30
0x35
0x41
59

Publicité

Table des Matières
loading