Pre-Installation Requirements; Technical Information - glass 1989 MIMESI-S Notice D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

• If the product is not used or installed in compliance with the
existing standards of the installed country.
• If the special maintenance is not carried out by qualifi ed
personnel.
Serial number (Figure A) to state in each intervention request.
Do not remove the sticker from the product!
Figure A
WARNING.
• Read the manual carefully in all its parts before using the
product.
• Keep this manual for further consultation.
• The manual is intended for diff erent models and versions, so
the product may look diff erent from the manual illustrations.
However the instructions remain unchanged.
• The company reserves the right to make any changes
considered suitable without notice or replacement.
• This product is intended only for the use for which it has been
designed. The manufacturer is not responsible for any damage
caused by improper usage.
• The product identification data (model, power, voltage,
manufacturer's name) are contained in the silver data plate
on the unit and on the warranty card. It is issued at the time
of testing.
• Make sure that the drain is always effi cient.
• Ensure that the fl oor around the product is always dry and
clean, to avoid slips or falls entering or editing the product
itself.
• Pay maximum attention when the surrounding fl oor is wet,
as there will be a potentially high risk of slipping. this, mainly,
when using soaps, shampoos, clearing detergents, etc..
• It is not advisable to use the shower cabin with water that is too
hot. Use water with a maximum temperature of 38°C.
• Who uses a steam bath frequently should periodically undergo
medical check-ups to ensure being in a good health status
• Steam bath must not be used by people aff ected by weak heart
condition, inner infl ammations, infectious diseases, epilepsy
and who have pacemakers.
• essential oils can be used only after being emulsed with
specifi c products to dissociate the oil itself.
• People aff ected by obesity, weak heart condition or blood
pressure disorders, circulation problems, diabetes, elderly
people or pregnant women should consult a doctor before
using the product.
• People who take medicines should consult a doctor before
using the product as some medicines may cause sleepiness,
aff ect heart beat, blood pressure and circulation.
• Do not use alcoholic substances, drugs or medicines before
and during the use of the product as they could cause
unconsciousness.
• This product is not intended to be used by persons (including
children) with reduced physical, sensory or mental capabilities
or lack of experience or knowledge, unless they have been
given appropriate supervision or instruction concerning use
of the appliance by a person responsible for their safety.
• WARNING: children may use the product unsupervised only
when its operation has been clearly explained to them and
they are able to use it safely while recognising the dangers
of misuse.
• When the product is not used, disconnect it completely by
turning off the double-pole switch installed on upstream the
appliance.
All measurements are in mm.

PRE-INSTALLATION REQUIREMENTS

The requested fl oor load is of Min. 200 Kg/m². The premises
fi tting the product must, therefore, meet this condition.
To prevent damaging the mixer parts, place a fi lter upstream of
the mixer.

TECHNICAL INFORMATION:

• Minimum fl ow pressure:
150 kPa (1,5 bar)
• Operating pressure:
350 kPa (max 3,5 bar)
• Recommended operating pressure: 250 kPa (2,5 bar)
• Hot water temperature:
max 60°C
The power supply box, to be connected to point C.P. (see Pre-
installation requirements) is supplied in all versions except the
manual version.
To make the electrical connection to the power supply box (only
for product versions supplied with the power supply box) use an
H07 RN-F cable with diameter of 2.5 mm².
When making the connection to the electrical mains, a double-
pole switch must also be fi tted near the appliance, upstream of
the power supply box, with contacts opening by at least 3 mm,
and suitable for 220/240 V 16 A.
The appliance must be connected to an electrical system
provided with a 0.03 A diff erential thermal breaker.
The product's supporting structure is metallic. An effi cient
ground system is therefore required, with sensitivity meeting
the relevant standards.
GROUNDWIRE.
The ground wire must be connected and fi xed permanently
to the electrical system.
EQUIPOTENTIAL CONNECTION.
The equipment must be connected to the equipotential
system of the room and duly fastened to its terminal to be
found in the product.
The
following
accessories
manufacturer) are required for installation:
a) Fittings to connect the mixer to the domestic water mains
(connection to mixer via ½" fi ttings) pipes provided in the
kit and no other types of piping must be used.
b) Fittings to connect the drain fl ush-mounted on the fl oor to the
shower enclosure drain siphon (connection via Ø 40 hose).
ROUTINE AND
SPECIAL MAINTENANCE
Use water up to a maximum of 60°C to maintain the shine of the
product over the years.
Use soft cloths and neutral non- abrasive liquid detergents
for cleaning. Do not use cloths with synthetic fi bres, abrasive
sponges, metal pads, solid and liquid detergents containing
abrasive substances, alcohol, acids for domestic use, acetone
or other solvents that can damage the surface.
In case of lime deposit it is advised to use lemon juice.