Steris Amsco V-Pro
Laryngoscope Blades and Handles are compatible with:
Amsco V-Pro 1 Low Temperature Sterilization System
Amsco V-Pro 1 Plus Low Temperature Sterilization System
Amsco V-Pro 1 Pro Max Temperature Sterilization System
Sterrad
Larynogoscope Blades and Handles are compatible with:
Sterrad 100nx System (Standard and Express Cycle)
Sterrad nx System (Standard Cycle)
Sterrad 1005 and 200 System (Short Cycle Outside US)
Sterrad 50 System
HANDLES
Cleaning/Sterilization:
Battery Handle withstand the same cold soak solution and autoclave ranges outlined in the blade section.
However, the batteries and lamp must be removed prior to disinfection/sterilization.
Battery Handles can withstand exposure to the ethlene oxide. Lamp may be cleaned with cotton ball damp-
ened in alcohol (IPA). The main handle and a cap will also withstand and exposure to ethylene oxide.
Do not allow excess fluid to seep into electrical contact, batteries must be removed before cleaning
& sterilization.
BLADE & HANDLE TEST PROCEDURE
Laryngoscope blades and handle should always be tested after cleaning/ disinfection/ sterilization and prior to
use. To test connect the laryngoscope blade to handle and pull it to the ON position as in Fig 2 if the unit fails
to light or flicker, check the lamp/ batteries and the electrical contacts, Be sure adequate supplies of spare
lamps, batteries and replacement parts are readily available if problem still persists, contact supplier please.
Warning
The above listed sterilization Guidelines, provided by GIMA are intended as procedures compatible
with specific materials. Sterilization must be performed to approved Hospital protocol. GIMA can not
guarantee sterility. This will be validated by the hospital and or sterilization equipment manufacturers.
Caution: read instructions (warnings) carefully
Keep in a cool, dry place
Manufacturer
Product code
Medical Device complies with Directive
93/42/EEC
Follow instructions for use
Disposal: The product must not be disposed of along with other domestic waste.
The users must dispose of this equipment by bringing it to a specific recycling point for electric and
electronic equipment.
For further information on recycling points contact the local authorities, the local recycling center or
the shop where the product was purchased. If the equipment is not disposed of correctly, fines or
penalties may be applied in accordance with the national legislation and regulations.
ENGLISH
WEEE disposal
Keep away from sunlight
Date of manufacture
Lot number
Consult instructions for use