Laryngoscopes conventionnels
Masquer les pouces Voir aussi pour 34301:

Publicité

Les langues disponibles

Les langues disponibles

PROFESSIONAL MEDICAL PRODUCTS
LARINGOSCOPI CONVENZIONALI
CONVENTIONAL LARYNGOSCOPES
LARYNGOSCOPES CONVENTIONNELS
KONVENTIONELLE LARYNGOSKOPE
LARINGOSCOPIOS CONVENCIONALES
LARINGOSCÓPIOS TRADICIONAIS
ΣYMBATIKA ΛΑΡΥΓΓΟΣΚΟΠΙA
Manuale d'uso e manutenzione - Use and maintenance book
Instructions de foncionnement et entretien - Betriebs und wartungs anweisungen
Manual de uso y mantenimiento - Manual de uso e manutenção
Εγχειριδιο χρησης και συντηρησης -
ATTENZIONE: Gli operatori devono leggere e capire completamente
questo manuale prima di utilizzare il prodotto.
ATTENTION: The operators must carefully read
and completely understand the present manual before using the product.
AVIS: Les opérateurs doivent lire et bien comprendre ce manuel
avant d'utiliser le produit.
ACHTUNG: Die Bediener müssen vorher dieses Handbuch
gelesen und verstanden haben, bevor sie das Produkt benutzen.
ATENCIÓN: Los operadores tienen que leer y entender
completamente este manual antes de utilizar el producto.
ATENÇÃO: Os operadores devem ler e entender
completamente este manual antes de usar o produto.
ΠΡΟΣΟΧΗ: Οι χειριστές αυτού του προϊόντος πρέπει να διαβάσουν και να
καταλάβουν πλήρως τις οδηγίες του εγχειριδίου πριν από την χρήση του.
34301 - 34302 - 34303 - 34305 - 34306 - 34307
34310 - 34311 - 34312 - 34313 - 34314 - 34317
34318 - 34319 - 34320 - 34321 - 34352 - 34354
Gima S.p.A.
Via Marconi, 1
20060 Gessate (MI) Italy
Made in Pakistan
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - export@gimaitaly.com
www.gimaitaly.com

Publicité

Table des Matières
loading

Sommaire des Matières pour Gima 34301

  • Page 1 ΠΡΟΣΟΧΗ: Οι χειριστές αυτού του προϊόντος πρέπει να διαβάσουν και να καταλάβουν πλήρως τις οδηγίες του εγχειριδίου πριν από την χρήση του. 34301 - 34302 - 34303 - 34305 - 34306 - 34307 34310 - 34311 - 34312 - 34313 - 34314 - 34317 34318 - 34319 - 34320 - 34321 - 34352 - 34354 Gima S.p.A.
  • Page 3 The laryngoscope blades are manufactured from antimagnetic 18/8- quality stainless steel type AISI 303/304 which is highly resistant to corrosion and conform to the ISO 7376 standard. GIMA blades are maintenance free and autoclavable up to 134°C / 5 min approximately for 2,000 times. USING THE BLADES Do not grip the lever when removing the blade.
  • Page 4: Care & Maintenance

    ENGLISH 4. In handle insert one positive end down, the other positive end up and reinstall the end cap. If handle light guide fails to light batteries may need to be reversed for correct polarity. 2.5V battery handles can be used with dry batteries as well as 2.5V rechargeable batteries CARE &...
  • Page 5 The above listed sterilization Guidelines, provided by GIMA are intended as procedures compatible with specific materials. Sterilization must be performed to approved Hospital protocol. GIMA can not guarantee sterility. This will be validated by the hospital and or sterilization equipment manufacturers.
  • Page 6: Caractéristiques

    Congratulations for purchasing a GIMA product. This product meets high qualitative standards both as re- gards the material and the production. The warranty is valid for 12 months from the date of supply of GIMA. During the period of validity of the warranty, GIMA will repair and/or replace free of charge all the defected parts due to production reasons.
  • Page 7: Procédure De Remplacement Des Piles

    ENGLISH PROCÉDURE DE REMPLACEMENT DES PILES 1. Dévisser le bouchon inférieur du manche et enlever les pilles 2. Pour une plus longue durée, il est conseillé de les remplacer par des piles alcalines. Il est également pos- sible d’utiliser des piles normales au carbone. 3.