Electrical connection
Mains voltage
Phase
Power frequency
Degree of protection
Protection class
Nominal power
Power protection (slow-blowing)
Dimensions and weights
Typical operating weight
Length x width x height
Ambient conditions
Ambient temperature
Device performance data
Tank content
Air quantity
Vacuum
Nominal width of the suction hose
Determined values in acc. with EN 60335-2-69
Hand-arm vibration value
Uncertainty K
Sound pressure level L
Uncertainty K
pA
Mains cable
Mains cable H07BQ-F
Part number (EU)
Cable length
Subject to technical modifications.
Declaration of Conformity
EU Declaration of Conformity
We hereby declare that the machine de-
scribed below complies with the relevant
basic safety and health requirements in the
EU Directives, both in its basic design and
construction as well as in the version
placed in circulation by us. This declaration
is invalidated by any changes made to the
machine that are not approved by us.
Product: Dry vacuum cleaner
Product: Wet/dry vacuum cleaner
Technical data
V
~
Hz
W
A
kg
mm
°C
l
l/s
kPa (mbar) 26 (260)
m/s
m/s
dB(A)
pA
dB(A)
mm
m
English
IVR-L 100/30 Sc IVR-L 100/40 Sc
400
3
50
IPX4
I
3000
16
141
855 x 760 x 1770 855 x 760 x 1890
+40
100
87.5
DN70
2
< 2.5
2
0.2
62
2
2
4 x 2.5
9.979-856.0
7.5
Type: 9.986-xxx
Type: 9.989-xxx
Currently applicable EU Directives
2006/42/EC (+2009/127/EC)
2014/30/EU
2011/65/EU
Harmonised standards used
EN 55014-2: 2015
EN 55014-1: 2017 + A11: 2020
EN 60335-1
EN 60335-2-69
EN IEC 61000-3-2: 2019
EN 61000-3-3: 2013 + A1: 2019
EN 61000-3-11: 2000
400
3
50
IPX4
I
4700
32
168
+40
100
137.5
14 (140)
DN70
< 2.5
0.2
71
2
4 x 2.5
9.981-557.0
7.5
17