Install The Hood - Broan EVOLUTION QP130 Serie Instructions

Masquer les pouces Voir aussi pour EVOLUTION QP130 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CENTER
RETAINING SCREW
OUTER
RETAINING SCREWS
7
NON-DUCTED INSTALLATION ONLY:
Remove Center Retaining Screw and loosen Outer
Retaining Screws holding Recirculation Slide Plate
in place. Pull out slide plate and replace and tighten
retaining screws to hold slide plate in new (non-ducted)
position.
8
NON-DUCTED INSTALLATION ONLY:
Purchase a set of (2) non-ducted filters from your local
distributor or retailer. Attach the non-ducted filters to the
aluminum mesh filters following instructions packed with
the non-ducted filters.
FOR NON-DUCTED INSTALLATIONS - Skip to "INSTALL
THE HOOD" .
3¼" X 10"
HORIZONTAL
KNOCKOUT
PLATE
9
DUCTED INSTALLATION ONLY:
Remove 3¼" x 10 vertical, 3¼" x 10" horizontal, or 7-inch
round knockout plate(s) as appropriate for your ducting
method.
MODELS QP130BL • QP130BLC • QP130SS • QP130SSC
QP130WW • QP130WWC • QP136BL • QP136SS • QP136WW
RECIRCULATION
SLIDE PLATE
7" ROUND
KNOCKOUT
PLATE (also
remove 3¼" x 10"
vertical plate)
3¼" X 10"
VERTICAL
KNOCKOUT
PLATE
TOP/BACK
EDGE OF
HOOD
7" ROUND
DUCT
PLATE
10 DUCTED INSTALLATION ONLY:
Attach 3¼" x 10" Damper/Duct Connector (if using 3¼"
x 10" duct) or 7" Round Duct Plate (if using 7-inch round
duct) over the knockout opening.
Note:
To accomodate off-center ductwork, the 3¼" x 10" damper/
duct connector can be installed up to ½" on either side
of the hood center and the 7" round duct plate can be
installed up to ½" on either side of the hood center.
Trim the flange on the duct connector or duct plate if it
interferes with the electrical cable clamp.
Install the 3¼" x 10" Damper/Duct Connector with the
Damper Flap Pivot nearest the Top/Back Edge of Hood.

INSTALL THE HOOD

WARNING
To reduce the risk of electrical shock, switch power off
at service panel. Lock or tag service panel to prevent
power from being switched on accidentally.
ELECTRICAL
WIRING BOX
COVER
Remove Electrical Wiring Box Cover from inside
11
of hood and appropriate Electrical Power Cable
Knockout from top or back of hood.
Page 4
3¼" X 10"
DAMPER /
DUCT
CONNECTOR
ELECTRICAL POWER
CABLE KNOCKOUT