Les langues disponibles

FAN FILTERS.
- Open the lantern's bonnet.
- Unscrew the screws.
- Withdraw the filters 1 & 2 .
- Clean the filters, dry.
- Then, replace the pieces.
• Cleaning frequency :
1
2
After every 50 hours.
CAUTION : The lighting unit should never be used
if the fans are not working. In case of a failure,
turn off the lighting unit and
search for the cause of the problem.
CHANGING THE IRIS CASSETTE.
- Unscrew the screw a .
- Lower the small tongue plate b .
- Withdraw the iris cassette.
- Put in the new iris cassette and the block into place.
- Replace the small tongue
- Then, tighten the screw a .
CHANGING THE INNER FILTER-FRAME (GLASS).
3
Soft glass.
4
Correction filter 5500K --> 3400K.
Warning : This filter holder is bent to an angle of 15°.
DO NOT STRAIGHTEN IT.
BALANCING.
- The balancing adjustment of the
lighting unit, is achieved by moving
the inner counterweight, which is
controled by the knob 5 .
GOBOS CHANGER SETTING.
NOTE.
Before adjusting, put a drop of breaking fluid onto the threads
of the setting screws.
CHANGING THE COLOUR FRAMES AND COLOURS.
c
Remove the colour frame from the slot.
d
To change a colour, open out the 4 clips.
e
Cutting out a colour gel = ø266.
(Use the model supplied).
22
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
All manuals and user guides at all-guides.com
TECHNICAL FILE
2500W HMI FOLLOW SPOT
b .
VALID SINCE : 30.07.02
1
b
a
5
4 3
Setting screws for gobo changer.
INSIDE THE ZOOM.
Positioning screw blocks the
gobo changer into place.