Robert Juliat ARAMIS+ Mode D'emploi page 12

Masquer les pouces Voir aussi pour ARAMIS+:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CONNECTIONS.
Mains voltage.
- Check the conformity of the power supply unit.
Rating plate 10 : Lamp power.
Lighting unit / Power supply connection.
- Connect the lamp cable
ballast and connector e to the lighting unit.
- Lock the cable C into the cable lock j .
- Place the lamp into position - refer to page 16.
- Engage the automatic breaker 3 and check that the protection
4 is well engaged.
- Plug the cable
8
to the mains. If the power is present, the
checklight 1 lights up immediately.
- Engage the automatic breaker 2 .
WARNING !
- Never open the lantern's bonnet when the lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when lamp in place.
12
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
All manuals and user guides at all-guides.com
TECHNICAL FILE
2500W HMI FOLLOW SPOT
A
i
e
PUSH
0/+10V.
DATA IN
DATA OUT
EM XLR4
EM XLR5
EF XLR5
g
h
f
j
C to the connector
7 of the
D
C
B
DESCRIPTION.
A 1013 B. - Motorized shutter version.
e - EM HARTING 16 x 16A power socket.
f - EM XLR 4 output 0/+10V. (extra)
g - EM XLR 5 input DATA.
h - EF XLR 5 output DATA.
i - Fuse (10,3 x 38 - 2A.).
B Power supply unit.
1 - Mains checklight.
2 - 6A automatic breaker.
3 - General 25A automatic breaker.
4 - 1A automatic breaker.
6 - Ventilation opening
(DON'T OBSTRUCT THE AIR GAPS).
7 - EF HARTING 16 x 16A - 2 latch connector.
8 - Mains cable 3 x 4 mm
9 - DMX lamp control module :
k - EM XLR5 input DATA.
l - EF XLR5 output DATA.
m - EF XLR5 output DATA luminaire
PUSH
PUSH
( For the connection configura-
tions : refer to page 20 & 26 ).
l
m
k
10 - Rating plate.
11 - Power supply selector :
208V. 60Hz, 230V. 50Hz & 245V. 50Hz.
Position locked by a screw.
C Lamp cable.
Cable H07 RN-F 19G1,5 mm
with 16 x 16A M/F HARTING connectors.
D Analogue fader control (0/+10V).
1013+ B
VALID SINCE : 30.07.02
Power supply unit
(P.S.U.)
2
(3m)+P17 32A. + T plug.
2
length 3m fitted

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1013+B1013+ bsB1013+ b

Table des Matières