Troubleshooting
Fault
Appliance does not work
at all
Appliance does not heat up Green switch indicator is lit
Appliance does not reach
the set temperature
If after these controls, the malfunctioning continues, it is advisable to contact your supplier for assistance.
In case of any doubt, always contact your supplier!
Technical specification
Item no.
Operating voltage and frequency
EN
Rated power
Protection class
Waterproof protection class
Temperature range
Ambient temperature
Capacity
Dimensions (W x D x H)
Net weight (approx.)
Remarks: Technical specification is subjected to change without prior notification.
Warranty
Any defect affecting the functionality of the ap-
pliance which becomes apparent within one year
after purchase will be repaired by free repair or re-
placement provided the appliance has been used
and maintained in accordance with the instructions
and has not been abused or misused in any way.
Your statutory rights are not affected. If the appli-
ance is claimed under warranty, state where and
8
Symptoms
Green switch indicator
not lit & orange heating
indicator not lit
& orange heating indicator
not lit
Green switch indicator is lit
& orange heating indicator
is lit, but excessive frying
time or temperature
207208
305x460x
(H)350mm
8.1 kg
Possible cause
Control panel not seated
properly on bracket
No mains power
Appliance is switched off
Microswitch defective
Thermostat set to a low
temperature
Hi-limiter (thermal cut-
out) tripped.
Hi-limiter (thermal cut-
out) defective.
Thermostat defective
Thermostat defective
209202
220-240V~ 50/60Hz
3500 W
Class I
IPX3
50 - 190°C
5 - 45˚C
8 L
305x515x
(H)350mm
8.6 kg
when it was purchased and include proof of pur-
chase (e.g. receipt).
In line with our policy of continuous product devel-
opment we reserve the right to change the product,
packaging and documentation specifications with-
out notice.
Possible solution
Properly seat the control panel
on the bracket
Check the electrical installation
Switch on the appliance
Contact your supplier
Set the thermostat to a higher
temperature
Reset the Hi-limiter (thermal
cut-out) (See RESET on page 5)
Contact your supplier
Contact your supplier
Contact your supplier
207307
209301
2x3500 W
16 L
605x460x
605x515x
(H)350mm
(H)350mm
20.5 kg
21.5 kg