No.
Error message
E115 Temperature Sensor
Error !
E116 Adjustment Error !
E119 Staff Blocked
E120 Image sensor Error!
E121 Adjustment Inverse
Staff Not Allowed!

8. Operation Messages

Operation message
Abort Measurement!
Wait! File System Clean Up!
Shut Down!
Sand Clock Icon
Operation Messages
Counter measure / causes
Cover the objective telescope with a hand and switch ON the instrument.
Hardware communication failed.
Carry out the adjustment with guided steps, make sure instrument is level
and staff is truly vertical in normal position. Collimation is out of correction
range.
Not enough barcode length for measurement.
Contact services.
Check the staff orientation and staff setting.
Counter measure / remark
Current measuring process is terminated.
Cleaning up of temporary files/system files.
System is switching OFF.