All manuals and user guides at all-guides.com
Risk of Unsafe Operation. Unit cycles automatically when
power is on. When servicing, you may be exposed to voltage
sources, compressed air, or moving parts. Before servicing unit unplug or
disconnect electrical supply to the air compressor, bleed tank of pressure,
and allow the air compressor to cool.
PROBLEM
Excessive
Pressure switch does not
tank pressure
shut Off motor when
- safety valve
compressor reaches
pops Off.
"cut-out" pressure.
Pressure switch "cut-out"
too high.
Air leaks at fit-
Tube fittings are not tight
enough.
tings.
Air leaks at or
Check valve seat damaged.
inside check
valve.
Air leaks at
Defective pressure switch
pressure switch
release valve.
release valve.
Air leaks in air
Defective air tank.
tank or at air
tank welds.
Air leaks
Leaking seal.
between head
and valve plate.
TROUBLESHOOTING
CAUSE
21 - ENG
CORRECTION
Move On/Auto/Off lever to
the "Off" position, if the outfit
does not shut Off contact a
Trained Service Technician.
Contact a Trained Service
Technician.
Tighten fittings where air can
be heard escaping. Check fit-
tings with soapy water solu-
tion. Do Not Overtighten.
A defective check valve results
in a constant air leak at the
pressure release valve when
there is pressure in the tank
and the compressor is shut
Off. Replace check valve.
Refer to the "To Replace or
Clean Check Valve" in the
"Service and Adjustment" sec-
tion.
Contact a Trained Service
Technician.
Air tank must be replaced. Do
not repair the leak.
Risk of
Bursting
Do not drill into, weld or
otherwise modify air tank or
it will weaken. The tank can
rupture or explode.
Contact a Trained Service
Technician.
A17970