Customer Responsibilities

Check Safety Valve
Drain Tank
Air Filter
Air compressor pump
intake and exhaust valves
1- more frequent in dusty or humid conditions
Risk of Unsafe
Operation. Unit
cycles automatically when power
is on. When servicing, you may
be exposed to voltage sources,
compressed air, or moving parts.
Before servicing unit unplug or
disconnect electrical supply to
the air compressor, bleed tank
of pressure, and allow the air
compressor to cool.
To ensure efficient operation and
longer life of the air compressor
outfit, a routine maintenance
schedule should be prepared
and followed. The following
routine maintenance schedule is
geared to an outfit in a normal
working environment operating
on a daily basis. If necessary, the
schedule should be modified to
suit the conditions under which
your compressor is used. The
modifications will depend upon the
hours of operation and the working
environment. Compressor outfits
in an extremely dirty and/or hostile
environment will require a greater
frequency of all maintenance checks.
NOTE: See Operation section for the
location of controls.
A17970

MAINTENANCE

Before
Daily
or after
each
each
use
use
To Check Safety Valve
does not work properly, over-
pressurization may occur, causing
air tank rupture or an explosion.
wear certified safety equipment:
ANSI Z87.1 eye protection (CAN/
CSA Z94.3) with side shields
1.
Before starting compressor, pull
the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve
is stuck or does not operate
smoothly, it must be replaced
with the same type of valve.
To Drain Tank
from noise. Air tanks contain
high pressure air. Keep face and
other body parts away from outlet
of drain. Use ANSI Z87.1 eye
protection (CAN/CSA Z94.3) when
draining as debris can be kicked up
into face. Use ear protection (ANSI
S12.6 (S3.19) hearing protection) as
air flow noise is loud when draining.
1.
Set the On/Auto/Off lever to "Off"
and unplug unit.
2.
Pull the regulator knob out and
turn counterclockwise to set the
outlet pressure to zero.
16- ENG
Every
Yearly
100
hours
1
Risk of Bursting.
If the safety valve
Risk from Flying
Objects. Always
Risk of Unsafe
Operation. Risk