All manuals and user guides at all-guides.com
Cooling System (not shown): This
compressor contains an advanced
design cooling system. At the heart of
this cooling system is an engineered
fan. It is perfectly normal for this fan
to blow air through the vent holes
in large amounts. You know that the
cooling system is working when air is
being expelled.
Air Compressor Pump (not shown):
Compresses air into the air tank.
Working air is not available until the
compressor has raised the air tank
pressure above that required at the
air outlet.
Check Valve: When the air compres-
sor is operating, the check valve is
"open", allowing compressed air to
enter the air tank. When the air com-
pressor reaches "cut-out" pressure,
the check valve "closes", allowing air
pressure to remain inside the air tank.
Check Valve
Pressure Release Valve: The pres-
sure release valve located on the side
of the pressure switch, is designed to
automatically release compressed air
from the compressor head and the
outlet tube when the air compressor
reaches "cut-out" pressure or is shut
Off. The
pressure
release
valve
allows
the motor
to restart
freely.
When the
motor
stops running, air will be heard
escaping from this valve for a few
seconds. No air should be heard
leaking when the motor is running, or
continuous leaking after unit reaches
"cut-out" pressure.
A17970
How to Use Your Unit
How to Stop:
1.
Set the On/Auto/Off lever to
"Off".
Before Starting
Break-in instructions
and understand this instruction
manual for safety, operation and
maintenance instructions.
damage may result if the follow-
ing break-in instructions are not
closely followed.
This procedure is required before
the air compressor is put into service
and when the check valve or a com-
plete compressor pump has been
replaced.
1.
Make sure the On/Auto/Off lever
is in the "Off" position.
NOTE: If quick connect is installed,
pull coupler back until it clicks to
prevent air from escaping through the
quick connect.
2.
Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the
Installation section of this
manual.)
3.
Open the drain valve fully (coun-
ter-clockwise) to permit air to
escape and prevent air pressure
build up in the air tank during the
break-in period.
Pressure
Release
NOTE: Always drain tank on a wash-
Valve
able surface or in a suitable container
to prevent damaging or staining sur-
faces.
4.
Move the On/Auto/Off lever to
"On/Auto" position. The com-
pressor will start.
14- ENG
Do not operate this
unit until you read
Risk of Unsafe
Operation. Serious