Dustbane Quiet Serie Manuel De Pièces Et D'opérations page 15

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CAUSE
1. Dust cover improperly installed.
2. Clogged hose or nozzle.
3. Hose not inserted fully.
4. Full or clogged dust bag.
5. Dirty filters.
6. Broken belt.
7. Belt not installed on motor shaft.
8. Worn agitator.
9. Hole in hose.
CAUSE
1. Bag improperly installed.
2. Bag torn.
CAUSE
1. Carpet/Bare floor selector in BARE FLOOR position.
2. Broken belt.
3. Tripped overload protector in nozzle.
4. Handle in full upright position.
CAUSE
1. Tool use restricts air flow.
2. New carpet fuzz clogged air path.
PROBLEM :
Poor job of dirt pickup.
PROBLEM :
Dust escapes the dust bag.
PROBLEM :
Agitator does not turn.
PROBLEM :
Airflow restricted with attachment use -or- sound changes.
SOLUTION
1. Properly install dust cover.
2. Clean hose or nozzle area.
3. Insert hose.
4. Replace dust bag.
5. Clean or replace secondary filter and/or replace exhaust filter.
6. Replace belt.
7. Install belt on motor shaft.
8. Replace agitator.
9. Replace hose.
SOLUTION
1. Properly install bag.
2. Replace bag.
SOLUTION
1. Select CARPET position.
2. Replace belt.
3. Remove any items that may be caught or jammed, then reset.
If vacuum cleaner starts and stops again, clean agitator and end
caps, then reset.
4. Move handle from upright position.
SOLUTION
1. Check tools for fuzz, lint, pet hair or other debris.
2. See CLOG REMOVAL section and clean hose.
15
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Quiet qs2

Table des Matières