Diagnostic Tests - Jenn-Air JDRP436HM Mode D'emploi

Masquer les pouces Voir aussi pour JDRP436HM:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

IMPORTANT: The following procedures may require the use of needle probes to measure voltage. Failure to use needle probes will damage the connectors. To
ease the process of measuring voltage and resistance, test points for each pin are accessible through the slots in the plastic beneath each CCU connector.
Test Name
Description
TEST #1
This test checks for incoming and
outgoing power to and from the
Main Control
main control. This test assumes
(ACU)
that proper voltage is present at
the outlet.
Example:
14 VDC output from ACU

Diagnostic Tests

Steps
1. Unplug range or disconnect power.
2. Remove door and toe panel to access main control.
3. Verify that ALL connectors are inserted all the way into the main control.
4. With a voltmeter set to AC, connect black probe to J5-2 (Neutral) and red probe to J5-1 (L1).
5. Plug in range or reconnect power.
If 120 VAC is present, unplug range or disconnect power and go to step 6.
If 120 VAC is not present, unplug range or disconnect power and check the AC power cord
for continuity.
6. Disconnect P9, use a voltmeter set to DC, connect black probe to P9-1 (GND) and red probe to
P9-5 (+14 V) on the board. Plug in range or reconnect power. If DC 14 V is not present, unplug
range or disconnect power and change main control. If DC 14 V is present, unplug range or
disconnect power.
7. Reassemble all parts and panels. Plug in range or reconnect power.
P6-1
L1
P9
VDC
GND
WIN
GND
1
17
Feedback for current sensing
POWERMAX
P6-5
P6-3
Power Supply
N

Publicité

Chapitres

Table des Matières
loading

Table des Matières