Danfoss Link FT Mode D'emploi page 7

Thermostat
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
Installation Guide
Installation
Operation mode
Danfoss Link™ FT supports two types of operation modes:
1 . ON/OFF switching: do not connect a floor sensor with
Danfoss Link™ FT in this modus .
2 . Heating regulation: when installing the Danfoss Link™ FT
you have to consider the type of heating and thus which
sensors should be used .
There are three options:
1 . Comfort heating: Constant temperature on the floor in
bathrooms and other rooms where a comfortable warm
surface is required . Install the Floor sensor and choose Floor
regulation for the room when doing the configuration .
2 . Total heating: Control of room temperature in living rooms
etc . Install the floor sensor and a Danfoss Link™ RS . Choose
Combined regulation when doing the configuration on the
Danfoss Link™ CC .
3 . No floor sensor: A floor sensor is not present, and cannot
be installed . You must install a Danfoss Link™ RS . Choose
Room regulation .
Be aware that temperature control is less accurate without a
floor sensor and that all Danfoss Link™ FT in a room need to
have the same sensor configuration .
Danfoss recommends always installing a floor sensor .
Note! Do not install electric floor heating system without a floor
sensor, when the heating element is installed on or beneath
wooden surfaces and other surfaces sensitive to temperature!