Closing The Door; Technical Data; Installation - AEG A60120GS4 Notice D'utilisation

Masquer les pouces Voir aussi pour A60120GS4:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Problem
The appliance does not
cool at all
Green indicator flashing

Closing the door

1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "Installation".
3. If necessary, replace the defective door gaskets. Contact the Service Center.

TECHNICAL DATA

Dimension
Rising Time
The technical information are situated in the rating plate on the internal left side of the
appliance and in the energy label.

INSTALLATION

WARNING!
Read the "Safety Information" carefully for your safety and correct operation of the ap-
pliance before installing the appliance.
All manuals and user guides at all-guides.com
Possible cause
Power does not reach the appli-
ance
The appliance is not switched on Switch on the appliance
There is no voltage in the mains
socket (try to connect another
appliance into it)
Plug is not connected to the
mains socket properly
There is no voltage in the mains
socket (try to connect another
appliance into it)
The appliance is not switched on Switch on the appliance
Temperature Regulator is not on Check the Temperature Regulator
Temperature sensor problem
Height
Width
Depth
Technical data
Solution
Try connecting another electrical
device to the power outlet
Call an electrician
Connect the mains plug properly
Call an electrician
Call the service personnel
850 mm
595 mm
635 mm
24 h
27

Publicité

Table des Matières
loading

Table des Matières