• Store Blowers indoors – when not in use, blowers should be stored indoors in dry,
locked-up place – out of reach of children.
2.10 SERVICE
• Have your power tool serviced by a qualified repair person using only identical
replacement parts. This will ensure that the safety of the power tool is maintained.
• Have the product checked by a qualified professional and repaired, if necessary, before
you operate it again.

2.11 RESIDUAL RISKS

• Familiarise yourself with the use of this product by means of this instruction manual.
Memorise the safety directions and follow them to the letter. This will help to prevent
risks and hazards. Always be alert when using this product, so that you can recognise and
handle risks early. Fast intervention can prevent serious injury and damage to property.
Switch off and disconnect from the battery if there are malfunctions.
• Even if all instructions are strictly followed, there are still some factors that could lead to
hazards, such as :
- Thrown out pieces of the work piece.
- Vibration injuries : use designated handles and try to reduce working time and
exposure.
- Injuries caused by noise : wear ear protection and reduce working time and exposure.
- Inhalation of dust and particles.
-Injury from flying objects from the blow tube airflow. Wear eye protection at all times.
If you experience any of these factors while using the machine, stop the machine consult
your doctor immediately
• Injuries may be caused or aggravated by prolonged use of a tool. When using any tool
for prolonged periods, ensure you take regular breaks.

3. TECHNICAL DATA

Model
Rated voltage (V d.c.)
Machine weigh (including battery pack)
Guaranteed sound power level (dB(A))
Measured sound power level (dB(A))
Sound pressure level(dB(A))
Working current
Maximum current
Recommended protection
No-load speed (min
-1
)
189
20VBL2-GT.1
18V d.c., Max 20V d.c.
1.8kg
92 dB(A)
89.0 dB(A), K=3dB(A)
69.0dB(A) KpA=3dB(A)
6-7A
10A
Protection with battery
10000-14000