Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

INSTALLATION MANUAL
President ZC Cast Front 536CXB
Approved for use with Valor heater model 530 only
Not compatible with 530INI/IPI insert engines
DANGER
!
A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and must be
installed for the protection of children and other at-risk
individuals.
Note: This kit must be installed or serviced by a qualified
installer, service agency or gas supplier. These instructions
are to be used in conjunction with the main installation
instructions for the above listed heater model.
Applications
The President ZC Cast Front 536CXB is intended to
install on the Valor Portrait 530 heater when installed as
a zero clearance fireplace.
The President ZC Cast Front 536CXB is NOT compatible
with the 530INI/IPI insert engine. If installing the 530
insert, use the President ZC Cast Front 536CXBI.
4001168-10
©2020, Miles Industries Ltd.
Portrait
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
INSTALLER: Leave this
manual with the appliance.
CONSUMER: Retain this
manual for future reference.
 WARNING
If the information in these
instructions is not followed
exactly, a fire or explosion
may result causing property
damage, personal injury or
loss of life.
1

Publicité

Table des Matières
loading

Sommaire des Matières pour Valor Portrait President ZC Cast Front 536CXB

  • Page 1 Applications The President ZC Cast Front 536CXB is intended to install on the Valor Portrait 530 heater when installed as a zero clearance fireplace. The President ZC Cast Front 536CXB is NOT compatible with the 530INI/IPI insert engine.
  • Page 2: Mantel Requirements

    The 536CXB President ZC Cast Front may be installed Applications with a combustible mantel provided clearances The Valor model 530 heater with the 536CXB President are maintained as indicated in the Dimensions and ZC Cast Front comes ready for installation as a zero...
  • Page 3: Dimensions & Clearances

    Dimensions & Clearances Ceiling 26-1/4” ‘A’ 20” Mantel Mantel 6-5/8” 1” max. See table dia. 1/2” min. 2” 11” min. Optional Top Outlet ‘B’ 1” max. 26” 1/2” min. ‘D’ ZC Stand-offs (framing plate) 2” ‘E’ 6-5/8” dia. 26” 36” min. to combustibles insul.
  • Page 4 Framing The President ZC Front comes supplied with a framing plate for zero clearance Bend Tabs out applications. The framing plate is painted for desired wall finish thickness black and may be left exposed beyond the perimeter of the cast iron front or may be covered with non-combustible material if desired.
  • Page 5 Rear vent framing Wall Finish 7-1/2” minimum This part of wall must be non-combustible 31-1/2” (cement board or to header & similar) wall finish (includes plinth - reduce by 7/8” if not using plinth) Top of finished Minimum 11” hearth or floor 26-1/4”...
  • Page 6 Installation Mount the framing plate to the Fit the top baffle under the top panel of the appliance appliance. case. Secure with 2 thread forming screws. Secure the framing plate and brackets to the sides of the appliance case with 4 thread cutting screws supplied.
  • Page 7 Fit the rear base support under the rear of the If the hooks have been shipped loose with the cast appliance attaching it to the appliance back front, fix them to the front at its top corners. Hang panel with 2 x ⅜” thread cutting (pointed end) the front on the appliance.
  • Page 8 Cleaning  WARNING Do not touch the barrier screen, the cast front or the glass while they are hot! Let the fireplace cool first before cleaning it. To clean the barrier screen and the cast front use a soft brush. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.
  • Page 9: Repair Parts List

    Repair Parts List Description Number Alternate no. Front Unit 568979 040A519 Door Hinge Bolt 568999 420K558 Ashpan Door 568989 540K048AZ Washer 532529 100B810 Magnet unit 569009 020A085 Front Casting 568929 050A255AZ Front Casting Hook RH 568949 330A923 Front Casting Hook LH 568939 330A922 Top Casting...
  • Page 10: Applications

    DIRECTIVES D’INSTALLATION Portrait Devanture de fonte President 536CXB Homologué pour usage avec les foyers Valor Portrait 530 seulement Incompatible avec les foyers encastrables 530INI/IPI DANGER INSTALLATEUR : Laissez cette notice avec l’appareil. CONSOMMATEUR : Conservez cette notice pour VITRE CHAUDE - RISQUE consultation ultérieure.
  • Page 11: Contenu Du Kit

    Exigences pour le manteau de cheminée Applications La devanture de fonte President ZC 536CXB peut être Le foyer Valor 530 combiné à la devanture de fonte installée avec un manteau de cheminée combustible à President ZC 536CXB est prêt à installer comme appareil condition de respecter les dégagements indiqués aux...
  • Page 12: Dimensions Et Dégagements

    Dimensions et Dégagements Plafond 26-1/4” ‘A’ 20” manteau Patte du manteau - Dia. 6-5/8” Max. 1” voir table min. 1/2” 2” Min. 11” Évacuation optionnelle ‘B’ Max. 1” 26” sur le dessus min.1/2” ‘D’ Écarteurs (encadrement) 2” ‘E’ Dia. 6-5/8” 26”...
  • Page 13 Encastrement pouces [mm] La devanture President ZC 536CXB est fournie avec une plaque d’encadrement pour applications à dégagement zéro. La plaque d’encadrement est peinte en noir Pliez les languettes et peut être exposée autour de la selon l’épaisseur de devanture ou elle peut être couverte Détail des languettes d’un matériau non-combustible si désiré.
  • Page 14: Encastrement Pour Installations À Évacuation Arrière

    Encastrement pour installations à évacuation arrière Finition du mur 7-1/2” minimum Cette partie du mur doit être non-combustible 31-1/2” (panneau de de la poutre ciment ou de tête et similaire) finition du mur (plinthe incluse - réduire de 7/8” si vous n’utilisez pas la plinthe) Surface du plancher fini...
  • Page 15 Installation Placez la plaque d’encadrement sur Placez le déflecteur du haut sous le panneau de l’appareil. dessus de la boîte de foyer. Fixez-le avec 2 vis Fixez-la aux côtés autoformeuses. de la boîte de foyer avec 4 vis auto-taraudeuses fournies. Vissez la plaque de l’extérieur à...
  • Page 16 Fixez le support de base arrière à l’aide de 2 vis Si nécessaire, vissez les crochets à l’arrière de la autoformeuses de ⅜”. devanture. Notez bien que les crochets droit et gauche sont différents. Accrochez la devanture de fonte aux coins supérieurs de la paroi intérieure de la boîte du foyer.
  • Page 17: Entretien

    Entretien  AVERTISSEMENT Ne touchez pas le pare-étincelles, la devanture ou la fenêtre lorsqu’ils sont chauds. Laissez le foyer refroidir avant de le nettoyer. Pour nettoyer le pare-étincelles et la devanture de fonte, utilisez une brosse souple. Si le pare-étincelles est endommagé, il doit être remplacé...
  • Page 18: Liste De Pièces

    Liste de pièces Description Numéro No. alternatif Qté Devanture complète 568979 040A519 Boulon, charnière du garde-cendres 568999 420K558 Garde-cendres 568989 540K048AZ Rondelle, charnière du garde-cendres 532529 100B810 Aimant 569009 020A085 Devanture de fonte 568929 050A255AZ Crochet, côté droit 568949 330A923 Crochet, côté...

Table des Matières