Specifications; General Specifications; Specifications Of Current Measurements - Chauvin Arnoux F 1N Mode D'emploi

Pince de courant
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1

GENERAL SPECIFICATIONS

Measurement range:
TRMS: 0.3 A to 400 A rms (up to 700 A for Sine)
Range overload limits:
400 A rms to 700 A rms or 1000 A peak
Ranges: 0 to 40.00 A and 0 to 400.0 A
Frequency:
- 10 Hz to 1 kHz (current measurement)
- 0.5 Hz to 10 kHz (frequency measurement)
Temperature: +23°C ±5°K
Humidity: 40 % to 75 % relative humidity
Crest factor:
- 2.5 max at 400 A, 45 to 65 Hz
- 5.0 max at 40 A, 45 to 65 Hz
Battery: 9 V ± 0.1 V
Storage temperature: -40°C to +70°C
Standards:
- IEC 1010-2-032 safety, protection from electric
shocks, dual isulation, maximum voltage of
conductors in relation to the earth 600 V, installa-
tion category I I I, degree of pollution 2.
- Electromagnetic compatibility:
EN50081-1: 92 Emission
EN50082-1: 92 Immunity
Safety markings: UL, CSA and GS
Service life (for an alkaline battery): 80 hours typical / 60 hours minimum
Maximum drop height: 1 m
Weight: 500 gr.

SPECIFICATIONS OF CURRENT MEASUREMENTS

Measurement error in the following reference range:
Frequency: 45 Hz to 65 Hz.
Position of conductor in the clamp: centred.
DC magnetic field: the earth's field.
See General Specifications for temperature, humidity rate and the reference battery voltage.

SPECIFICATIONS

49
76 mm
2 busbars
50 x 5 mm
2 cables
Æ 25.4 mm
cable
max.
Æ 42 mm
64 mm
88.6 mm
98 mm
33.7 mm
43.7 mm

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

F 2nF 3n

Table des Matières