Cleaning And Maintenance; Technical Specifications - HQ Power VDPDP152 Notice D'emploi

Bloc de puissance dmx 4 canaux
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

The device can perform several functions, depending on the setting of the last DIP switch (n° 10). See table above
for the different settings.
When all connections are made, connect the device to the mains power and turn on the circuit breaker. Adjust the
output of the analogue controller to adjust the corresponding load on the selected channel.
Note that each channel has an output LED to show the actual status of the channel.
6. Fuse
Do not try to repair the device. You can only open the housing to replace a blown fuse with an identical one.
Unscrew the cover of the fuse holder with a screwdriver, remove the old fuse, insert the new one and close the fuse
compartment again. Order spare parts from your local dealer.

7. Cleaning and Maintenance

1. All screws for installing the devices or parts of the device have to be screwed down tight and must not be
corroded.
2. Neither the housing nor the mounting supports should not be modified or tampered with.
3. The electric power supply cables must be undamaged. Have the device installed by a qualified technician.
4. Disconnect the device from the mains prior to maintenance activities.
5. Wipe the device regularly with a moist cloth. Do not use alcohol or solvents.
6. Entrust a qualified technician with the maintenance of this device. Contact your dealer for spare parts if
necessary.

8. Technical Specifications

Power Supply
Number of channels
Maximum total load
Maximum total current
Maximum load per channel
Output connections
VDPDP152_v3
Fig. 3
FUNCTION = FUNCTIE = FONCTION
1
2
3
4
any one of the DIP switches 1-9 is ON, DMX parallel
all the DIP switches 1-9 are OFF, auto parallel
any one of the DIP switches 1-9 is ON, DMX
all the DIP switches 1-9 are OFF, auto
5
6
7
8
DMX ADDRESS = DMX ADRES = ADRESSE DMX
1 2 3 4 5 6 7 8 9 start. address
1 0 0 0 0 0 0 0 0
0 1 0 0 0 0 0 0 0
1 1 0 0 0 0 0 0 0
0 0 1 0 0 0 0 0 0
1 0 1 0 0 0 0 0 0
1 1 1 1 1 1 1 1 1
230Vac / 50Hz
4
max. 3520W
max. 16A
1100W
4 x SCHUKO socket
4
9
10
1
0
1
2
3
4
5
512
VELLEMAN

Publicité

Table des Matières
loading