Frigidaire CFEF2422RS Notice D'installation
Frigidaire CFEF2422RS Notice D'installation

Frigidaire CFEF2422RS Notice D'installation

Cuisinière électrique de 600mm (24")

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

24" (600 mm) ELECTRIC RANGE INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Clearances and Dimensions
1. Provide adequate clearances between the range and adjacent combustible surfaces.
2. Location—Check location where the range will be installed. Check for proper electrical supply, and the stability
of the floor.
3. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must
be solid and level.
FRONT
VIEW
(92 cm)
24"
(61 cm)
3-3/4" (9.5 cm)
*30" (762 mm) MINIMUM CLEARANCE BETWEEN THE TOP OF THE COOKING SURFACE AND THE BOTTOM OF AN UNPROTECTED
WOOD OR METAL CABINET; OR 24" (610 mm) MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET IS PROTECTED BY NOT
LESS THAN 1/4" (6 mm) FLAME RETARDANT MILLBOARD COVERED WITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015"
(0.4 mm) STAINLESS STEEL, 0.024" (0.6 mm) ALUMINUM OR 0.020" (0.5 mm) COPPER. 0" (0 mm) CLEARANCE IS THE MINIMUM FOR
THE REAR OF THE RANGE. FOLLOW ALL DIMENSION REQUIREMENTS PROVIDED ABOVE TO PREVENT PROPERTY DAMAGE,
POTENTIAL FIRE HAZARD, AND INCORRECT COUNTERTOP AND CABINET CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE SPACE
LOCATED ABOVE THE SURFACE UNITS SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE PROVIDED, THE RISK CAN
BE REDUCED BY INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5" (127 mm) BEYOND THE
BOTTOM OF THE CABINETS.
P/N 809019201 REV A (1502)
(For 4 Wire, 60 Hz. Systems)
(61 cm)
30"
(76 cm)
Minimum
Minimum to wall
on either side of
1"
range above
(2.5 cm)
36'' (914 mm)
height.
36"
24"
(61 cm)
All dimensions for electrical outlet location
are maximum.
Shaded area
shows where the electrical outlet must be
installed
for flush to the wall installation.
10"
(25 cm)
Wall
Edge
24"
Minimum to
cabinets on
18"
either side of
(46 cm)
range.
0" (0 mm) clearance below cooking top and at rear of range.
35"
35"
89 cm
89 cm
1
SIDE
VIEW
13"
33 cm
Maximum depth
for cabinets
above range top.
25"
64 cm
23.5"
23-5/8"
60 cm
60 cm
41.5"
105 cm
Maximum
door open
English - Pages 1-4
Français - Pages 5-8

Publicité

Table des Matières
loading

Sommaire des Matières pour Frigidaire CFEF2422RS

  • Page 1 24" (600 mm) ELECTRIC RANGE INSTALLATION INSTRUCTIONS (For 4 Wire, 60 Hz. Systems) INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Clearances and Dimensions 1.
  • Page 2: Before Starting

    24" (600 mm) ELECTRIC RANGE INSTALLATION INSTRUCTIONS (For 4 Wire, 60 Hz. Systems) IMPORTANT SAFETY Before Starting Tools You May Need INSTRUCTIONS For leveling legs and Anti-Tip Bracket: If the information in this manual is not followed exactly, a fire or electrical shock may result causing property •...
  • Page 3: Electrical Connection Requirements

    24" (600 mm) ELECTRIC RANGE INSTALLATION INSTRUCTIONS (For 4 Wire, 60 Hz. Systems) B. Drill Pilot Holes and Fasten Bracket - Drill a 1/8" (3 mm) pilot hole where screws are to be located. If bracket is to be mounted to the wall, drill pilot hole at an approximate 2.
  • Page 4: Model And Serial Number Location

    24" (600 mm) ELECTRIC RANGE INSTALLATION INSTRUCTIONS (For 4 Wire, 60 Hz. Systems) Model and Serial Number Location The serial plates are located on the oven front frame, visible when the door ir open, and on the back of the appliance near the bottom.
  • Page 5: Dimensions Et Espaces Libres

    NOTICE D’INSTALLATION POUR CUISINIÈRE ÉLECTRIQUE DE 600mm (24") (pour les systèmes 60 Hz à 4 fils) L'INSTALLATION ET L'ENTRETIEN DOIVENT ÊTRE EFFECTUÉS PAR UN INSTALLATEUR QUALIFIÉ IMPORTANT: À CONSERVER POUR CONSULTATION PAR L'INSPECTEUR EN ÉLECTRICITÉ. LISEZ ET CONSERVEZ CES INSTRUCTIONS POUR CONSULTATION FUTURE. Dimensions et espaces libres 1.
  • Page 6: Directives Importantes De Sécurité

    NOTICE D’INSTALLATION POUR CUISINIÈRE ÉLECTRIQUE DE 600mm (24") (pour les systèmes 60 Hz à 4 fils) DIRECTIVES IMPORTANTES DE Avant de commencer SÉCURITÉ Outils dont vous aurez besoin Pour les pattes de mise à niveau et le support de contrerenversement Un feu ou une électrocution peut survenir et être la cause de dommages à...
  • Page 7: Exigences Du Raccordement Électrique

    NOTICE D’INSTALLATION POUR CUISINIÈRE ÉLECTRIQUE DE 600mm (24") (pour les systèmes 60 Hz à 4 fils) 1,7 cm B. Percez les trous d’alignement et fixez le support - Percez un trou de 3 mm (1/8") aux endroits où les vis seront Côté...
  • Page 8: Soins, Nettoyage Et Entretien

    NOTICE D’INSTALLATION POUR CUISINIÈRE ÉLECTRIQUE DE 600mm (24") (pour les systèmes 60 Hz à 4 fils) Emplacement du no. de modèle / no. de série Les plaques de séries sont situées sur le cadre avant du four, visibles lorsque la porte est ouverte, et à l'arrière, au bas de l'appareil.

Ce manuel est également adapté pour:

Cfeh2411uwCglef379gc

Table des Matières