installation option 1 - open enclosure (enclosure stops short of the ceiling)

Installation Option 1 (open enclosure) leaves a complete air outlet opening above the enclosure to provide the
necessary air circulation path for the Dynamic Heat Control™ system. This has been found to be well accepted
with respect to fi nal appearance and offer minimal distraction. It also allows for effi cient circulation of air within the
room. This option offers the simplest method for framing and installation. Limit the air outlet opening height to 4"
to reduce the risk of items inadvertly falling into the enclosure. The air outlet opening must extend around the
entire perimeter, or the entire front face of the enclosure, where the enclosure runs from wall to wall.
DYNAMIC HEAT
CONTROL™ AIR
OUTLET OPEN-
ING IS HOT WHEN
APPLIANCE IS
OPERATING!
Air outlet opening
must be located out of reach of
the user. Air outlet must not be
restricted by furnishings or decor.
2.2

installation option 2 - front opening

Installation Option 2 (front opening) requires an air outlet opening to be framed no more than 1.5" below the
enclosure top to avoid trapping heat in the upper areas and the air outlet opening centered on the appliance center.
Minimum air outlet opening dimensions must be followed. Framing the air outlet opening lower will overheat the
appliance, the enclosure, and fi nishing material.
DYNAMIC HEAT
CONTROL™ AIR
OUTLET OPEN-
ING IS HOT WHEN
APPLIANCE IS
OPERATING!
Front air outlet opening must
be located out of reach of the
user. Air outlet must not be
restricted by furnishings or
decor.
Air outlet opening is required to be
centered with the appliance.
(Q x R)*
L
*Free area. Any trim edging or fi nishing must not reduce or restrict minimum area. Grills, grates,
louvres, or other unapproved covers are not permitted and will cause a fi re hazard.
NOT suitable for Dynamic Heat Control™ Plus
Suitable for Dynamic Heat Control™ Plus
(Q x R)*
L
MINIMUM AIR OUTLET OPENING DIMENSIONS
EX36
112 sq. in. minimum (Q must be 2-3")
installation planning
2-4"
6" min.
Wall mounted
object (picture
frame, appli-
ance, etc.)
2 1/2"
min.
0-1.5" Max.
2-3"
6" min.
Wall mounted
object (picture
frame, appli-
ance, etc.)
72"
ceiling
RECOMMENDED
ceiling
enclosure top
must be installed
ALTERNATIVE
EX42
W415-2753 / 10.23.19
EN
5