Multimetrix DMM 210 Notice De Fonctionnement page 31

Multimètre industriel
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
Chapter II
Function
Range
Resolution
Resistance 600 Ω
0,1 Ω
6 kΩ
0,001 kΩ
60 kΩ
0,01 kΩ
600 kΩ
0,1 kΩ
6 MΩ
0,001 MΩ
60 MΩ
0,01 MΩ
Frequency
9,999 Hz
0,001 Hz
(electronic)
99,99 Hz
0,01 Hz
999,9 Hz
0,1 Hz
9,999 kHz
0,001 kHz
99,99 kHz
0,01 kHz
999,9 kHz
0,1 kHz
9,999 MHz
0,001 MHz
Sensitivity :
0,8 Vrms min. @ 20 % to 80 % duty cycle and
F < 100 kHz ;
5 Vrms min. @ 20 % to 80 % duty cycle and
F > 100 kHz
Frequency
10,00-400 Hz 0,01 Hz
(electrical)
Sensitivity : 15 Vrms
Duty cycle
0,1 to 99,9 % 0,1 %
Pulse width : 100 µs - 100 ms
Frequency : from 5 Hz to 150 kHz
 Accuracy features include two elements:
(% R reading): accuracy of the measurement circuit
(+D figures):
ADC accuracy
DMM210
Authorized
Accuracy
overload
protection
±(0,3 % R + 4 D)
1 000 V
±(0,5 % R + 20 D)
±(0,1 % R + 1 D)
1 000 V
±(0,5 % R)
1 000 V
±(1,2 % R + 2 D)
1 000 V
29

Publicité

Table des Matières
loading

Table des Matières