Clean the device using a damp cloth, to which you can
apply a little detergent if necessary.
Do not use abrasive detergents and never immerse
the unit in water.
Important
• Ensure that no water penetrates inside the unit!
• Do not put the device or accessories in a dishwasher.
• Do not touch the unit with wet hands while it is
plugged in; do not allow any water to be sprayed
onto the unit. The unit must be operated only when
it is completely dry.
• Do not spray any liquids into the ventilation slots. Any
liquid that penetrates into the unit can damage the
electrical parts or other components of the nebuliser
and impair the function of the device.
Condensation, care of the hose
Depending on the environmental conditions, con-
densation may collect in the hose. To prevent against
bacterial growth and to ensure effective therapeutic
use, this moisture must always be removed. To remove
moisture from the hose, proceed as follows:
• Remove the hose [8] from the atomiser [9].
• Leave the hose plugged into the nebuliser [6].
• Run the nebuliser until all the moisture has been dis-
placed by the flow of air.
• In the event of significant contamination, replace the
hose.
Disinfection
Follow the steps listed below carefully in order to
disinfect your atomiser and the accessories. It is ad-
visable to disinfect the individual components after
the last time they are used each day at the latest.
(For disinfection, you will simply require a small
amount of clear vinegar and distilled water).
First clean the atomiser and the accessories as
described under "Cleaning".
Make up a vinegar solution consisting of 1⁄4 vin-
egar and 3⁄4 distilled water. Ensure that there is
sufficient solution to fully immerse all parts such
as the nebuliser, mask, and mouthpiece.
Leave the components in the vinegar solution for
30 minutes.
Rinse the atomiser and the individual components
(mask/mouthpiece etc.) with water.
Carefully dry all components using a soft cloth.
Once all components are fully dry, reassemble
the atomiser and place the components in a dry,
sealed container.
All manuals and user guides at all-guides.com
Please ensure that the parts are completely dried af-
ter cleaning, otherwise the risk of bacterial growth is
increased.
Drying
• Place the individual components on a dry, clean and
Material resistance
• As with all plastic components, frequent use and
• When choosing a cleaning or disinfecting agent, note
Warehousing
• Do not store the nebuliser in a damp atmosphere
• Store and transport the nebuliser away from direct
Storage
• The accessories can be safely stored in the acces-

9. Disposal

In the interest of environmental protection, do not dis-
pose of the device in household waste.
Please dispose of the device in accordance with
EU directive 2002/96/EC – WEEE (Waste Elec-
trical and Electronic Equipment).
If you have any questions, please contact the
local authorities responsible for waste disposal.
16
Note
absorbent surface and allow to dry completely (for
at least 4 hours).
cleaning of the atomiser and the accessories can
lead to a certain amount of wear. Over time, this can
alter the aerosol properties and may eventually affect
the efficiency of therapy. We therefore recommend
that you replace the atomiser once a year.
the following: Only use mild cleaning or disinfect-
ant agents in the quantities recommended by the
manufacturer.
(e.g. in the bathroom) or transport it together with
damp objects.
sunlight.
sories compartment [4]. Store the device in a dry
place, if possible in its original packaging.