Lenze 9371BB Manuel page 13

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Show/Hide Bookmarks
Change parameters
1. Change from the menus to the code level using the arrow keys
"Code" is displayed.
2. Select output AIN2/OUT (selection number 55) using
subcode.
3. Change to the parameter level using PRG."Para" is displayed.
4. Select output AIN2/OUT (selection number 55) using
(small, black bar) under the number to be changed.
5. Select output AIN2/OUT (selection number 55) using
6. Repeat 4. and 5. to change other numbers, if ncessary.
7. Accept parameters. The way of accepting the changed parameterr is displayed in
front of the parameter:
Display in front of the parameter Controller uses the new value
p
p
SH+PRG
SH+PRG
V
8. Press
twice to go to the code level. "Code" is displayed.
You can establish a user menu with max. 32 codes which you use
frequently under C0517.
• The number before the comma is the code number.
• The number after the comma is the subcode.
• Code-subcode combinations are allowed only once.
Save parameter set
You have to save the modified parameters if you do not want to loose them after mains
disconnection.
• You can establish up to four parameter sets, e.g. if you process different materials
on a machine or if this is required by different operating states (setup mode,
"stand-by").
• If you need only one parameter set, save the modifications permanently under
parameter set 1, since the controller automatically loads parameter set 1 after
mains connection.
How to proceed
1. Change from the menus to the code level using the arrow keys.
"Code" is displayed.
2. Select output AIN2/OUT (selection number 55) using
3. Change to the parameter level using PRG.
"Para" is displayed.
4. Set parameter to 1 using
Note: If the parameter set is to be saved under another number, select 2, 3, or 4
instead of 1.
T
V
+
5. Press
"OK" is displayed for approx. 1 s.
Now your settings are saved permanently under parameter set 1 (or 2, 3. 4).
Further information on parameter setting can be obtained from the
corresponding Operating Instructions for the controller.
Change/Save parameters
immediately, during the change
after pressing
Acknowledgement: ok in the display
S
Press
T
Press
Acknowledgement: ok in the display
U
Press
z
y
or
(also possible during operation).
.
z
Y
z
T
V
+
.
to inhibit the controller.
V
+
.
to enable the controller.
z
- 5 -
z
y
Y
,
,
or
y
or
select code or
Z
or
move the cursor
y
or
change number.
y
or
select C0003.
MA9371BB 2.0